{"product_id":"ge-fanuc-ic200mdl632-versamax-discrete-input-module","title":"GE Fanuc IC200MDL632 VersaMax Discrete Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDL632\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDL632\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for high-voltage DC binary signal acquisition within VersaMax PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Various\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg (0.31 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax single-slot footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA maximum backplane current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channel Count\u003c\/td\u003e\n\u003ctd\u003e16 individually isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Signal\u003c\/td\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e1.7 mA typical at 125 VDC; 2.2 mA typical at 150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e74 KΩ typical at 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Configuration\u003c\/td\u003e\n\u003ctd\u003ePositive (sourcing) and Negative (sinking) logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Filter Time\u003c\/td\u003e\n\u003ctd\u003e0 ms, 1.0 ms, 7.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Response Time\u003c\/td\u003e\n\u003ctd\u003e0.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation Rating\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003eNone required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL632 packs 16 individually isolated 125 VDC channels into a single module slot, expanding I\/O density scaling across VersaMax backplane carrier assemblies. The internal bus interface transfers binary state updates at rapid backplane bus communication velocity during system scan execution. Optical isolation blocks prevent high-voltage field spikes from compromising internal backplane communications, while total hardware compliance ensures complete firmware flash compatibility across VersaMax CPU families.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200MDL632 require an external power supply for internal logic operations?\u003c\/p\u003e\n\u003cp\u003eA: No, the module receives operational power directly from the VersaMax PLC backplane bus, drawing a maximum of 80 mA. Field signals are powered by external field loops up to 150 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How does individual channel isolation benefit overall system availability on the IC200MDL632?\u003c\/p\u003e\n\u003cp\u003eA: Channel-to-channel isolation rated at 250 VAC continuous ensures that a fault or open circuit on a single input channel does not impact adjacent channels, allowing remaining field inputs to continue operating normally.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Installation\u003c\/strong\u003e: Seat the module onto its matching VersaMax I\/O carrier terminal structure and apply firm pressure until the locking tabs snap securely onto the backplane rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e125 VDC Field Wiring\u003c\/strong\u003e: Wire discrete input devices (such as auxiliary contacts or pushbuttons) to the carrier terminals. Positive and negative logic configurations are supported per channel; ensure high-voltage 125 VDC field wiring is routed away from low-voltage analog cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding Verification\u003c\/strong\u003e: Connect the carrier frame ground screw to protective earth to enable full 1500 VAC transient isolation between user inputs, backplane logic, and enclosure ground.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43833435324506,"sku":"IC200MDL632","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200MDL632.png?v=1786527742","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-ic200mdl632-versamax-discrete-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}