{"product_id":"ge-fanuc-ic693prg300-series-90-30-handheld-programmer","title":"GE Fanuc IC693PRG300 Series 90-30 Handheld Programmer","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693PRG300\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693PRG300\u003c\/strong\u003e Handheld Programmer, operates as a dedicated hardware component for direct logic instruction entry and system parameter monitoring within Series 90-30 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693PRG300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.75 lbs (0.34 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eHandheld portable footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC supply voltage rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Technology\u003c\/td\u003e\n\u003ctd\u003eLCD display (2 lines x 16 characters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad Configuration\u003c\/td\u003e\n\u003ctd\u003e42 keys (6 x 7 tactile feedback keypad)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003e4 modes (Program Mode, Protection Mode, Data Mode, Configuration Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e15-pin D-type serial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Language\u003c\/td\u003e\n\u003ctd\u003eStatement List (SL) language\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Architecture\u003c\/td\u003e\n\u003ctd\u003eExpandable non-volatile memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterconnect Distance\u003c\/td\u003e\n\u003ctd\u003e2 meters (6 feet) recommended cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Interface Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC693PRG300 interfaces directly with Series 90-30 power supply serial ports via a 15-pin D-type connector to maintain real-time register access and data transfer. Utilizing a 5 VDC supply rail sourced through the serial link, the unit executes code compilation in Statement List language without degrading backplane bus communication velocity. Onboard firmware flash compatibility and non-volatile memory storage retain user programs and system configurations through power cycles. Four selectable operational modes (Program, Protection, Data, and Configuration) provide low-latency execution for field parameter monitoring and program transfers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the IC693PRG300 powered during field operation?\u003c\/p\u003e\n\u003cp\u003eA: The handheld programmer operates on a 5 VDC supply voltage rating, drawing power directly through the 15-pin D-type serial cable connection attached to the CPU or power supply port.\u003c\/p\u003e\n\u003cp\u003eQ: What programming language and memory types are supported by this unit?\u003c\/p\u003e\n\u003cp\u003eA: The unit utilizes Statement List (SL) language for code entry and program edits, backed by expandable non-volatile memory that preserves stored data when disconnected from power.\u003c\/p\u003e\n\u003cp\u003eQ: What are the cable length recommendations for connecting the programmer to a PLC?\u003c\/p\u003e\n\u003cp\u003eA: GE Fanuc specifies a recommended cable length of 2 meters (6 feet) using the standard 15-pin D-type serial interconnect to ensure signal integrity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the PLC system serial port is accessible and free of debris prior to attaching the programming interface cable.\u003c\/li\u003e\n\u003cli\u003eAlign the 15-pin D-type connector with the mating port on the Series 90-30 power supply or CPU baseplate.\u003c\/li\u003e\n\u003cli\u003eTighten the connector jack screws finger-tight to secure electrical grounding and prevent accidental disconnection during operation.\u003c\/li\u003e\n\u003cli\u003eVerify that the cable run does not exceed the recommended 2-meter limit to prevent voltage drop and serial data distortion.\u003c\/li\u003e\n\u003cli\u003eUse the 42-key tactile keypad to select between Program, Protection, Data, and Configuration modes depending on the field servicing procedure required.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43738202570842,"sku":"IC693PRG300","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693PRG300.png?v=1785134005","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-ic693prg300-series-90-30-handheld-programmer","provider":"SpareOil Automation","version":"1.0","type":"link"}