{"product_id":"ge-fanuc-ic694alg233-pacsystems-rx3i-analog-current-input-module","title":"GE Fanuc IC694ALG233 PACSystems RX3i Analog Current Input Module","description":"\u003cp\u003eConfigured for multi-channel analog signal acquisition in PACSystems RX3i platforms, the \u003cstrong\u003eGE Fanuc IC694ALG233\u003c\/strong\u003e (\u003cstrong\u003eIC694ALG233\u003c\/strong\u003e Analog Current Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694ALG233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.81 lbs (0.37 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot RX3i module width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 mA internal backplane power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 single-ended channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eAnalog current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Format\u003c\/td\u003e\n\u003ctd\u003e16-bit signed integer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Requirement\u003c\/td\u003e\n\u003ctd\u003e20 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5% to 95% relative humidity (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 m MSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC694ALG233 interface optimizes backplane bus communication velocity across PACSystems RX3i chassis layouts by transferring converted 16-bit integer values directly into the main CPU memory register table. High-density I\/O density scaling allows up to 16 single-ended analog current channels to be continuously sampled within a single backplane slot. The module requires an external DC user supply between 20 and 30 VDC to power input loops, maintaining an internal current draw of 120 mA from the backplane supply. Firmware flash compatibility ensures seamless backplane address mapping during local rack execution or remote expansion drop execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What external power supply limits apply to the IC694ALG233 analog current input module?\u003c\/p\u003e\n\u003cp\u003eA: The module requires an external user DC supply within the range of 20 to 30 VDC for input channel operation.\u003c\/p\u003e\n\u003cp\u003eQ: How is analog measurement data formatted across the backplane bus?\u003c\/p\u003e\n\u003cp\u003eA: Analog inputs are converted and converted into a 16-bit signed integer format for register processing by the RX3i CPU.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane current consumption characteristics for this module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 120 mA of current directly from the internal RX3i backplane power bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the RX3i backplane rack and de-energize external field current loop supplies before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing card edges with the targeted slot in the RX3i baseplate, pressing the unit firmly until the rear connector latches into the backplane bus.\u003c\/li\u003e\n\u003cli\u003eTighten the top and bottom panel retention screws to secure the module mechanically and ensure continuous frame grounding.\u003c\/li\u003e\n\u003cli\u003eRoute signal wires separately from high-voltage AC conductors using shielded twisted-pair wiring for all 16 single-ended input loops.\u003c\/li\u003e\n\u003cli\u003eGround signal cable shielding at a single chassis ground point near the cabinet entry to prevent ground loop noise interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43737498910810,"sku":"IC694ALG233","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694ALG233.png?v=1785131423","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-ic694alg233-pacsystems-rx3i-analog-current-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}