{"product_id":"ge-fanuc-ic694mdl250-pacsystem-rx3i-discrete-input-module","title":"GE Fanuc IC694MDL250 PACSystem RX3i Discrete Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL250\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC694MDL250\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for 120 VAC discrete signal detection within PACSystem RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694MDL250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.23 kg (0.50 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RX3i single-slot module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 mA at 5 VDC (from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16, individually isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (47 to 63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e70 to 132 VAC \/ 6 mA (7 mA typical per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e0 to 20 VAC \/ 2.5 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Times\u003c\/td\u003e\n\u003ctd\u003eOn: 30 ms max \/ Off: 45 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Input Filter\u003c\/td\u003e\n\u003ctd\u003e20 ms to 2540 ms in 20 ms increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical \u0026amp; Channel Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Connectors\u003c\/td\u003e\n\u003ctd\u003eIC694TBBx32 or IC694TBSx32 terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL250 communicates with the PACSystem RX3i CPU via the backplane bus, transferring the status of all 16 isolated AC channels in a single backplane scan cycle. Configurable input filtering times (adjustable from 20 ms to 2540 ms in 20 ms increments) are pushed directly from the CPU to mitigate field contact bounce and line noise. Dedicated firmware flash compatibility enables real-time diagnostic reporting of field-side terminal block status back to the host CPU while keeping backplane power draw at 60 mA.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the backplane power requirement for the IC694MDL250 module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum current of 60 mA from the 5 VDC backplane bus when all 16 input channels are energized.\u003c\/p\u003e\n\u003cp\u003eQ: Are the input channels on the IC694MDL250 grouped or individually isolated?\u003c\/p\u003e\n\u003cp\u003eA: All 16 channels are individually isolated from each other and provide 250 VAC continuous (1500 VAC for 1 minute) isolation between field wiring and the backplane logic.\u003c\/p\u003e\n\u003cp\u003eQ: How are input filter settings configured on this module?\u003c\/p\u003e\n\u003cp\u003eA: Filter settings are configured through system software and transferred from the RX3i CPU to the module in 20 ms increments, ranging from 20 ms to 2540 ms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect main power to the PACSystem RX3i rack prior to mounting or removing the IC694MDL250 module to prevent connector damage.\u003c\/li\u003e\n\u003cli\u003eAlign the module card guide with the baseplate slot and push until the retaining mechanism latches onto the rack.\u003c\/li\u003e\n\u003cli\u003eWire field inputs using approved IC694TBBx32 or IC694TBSx32 terminal blocks, ensuring signal cables maintain physical separation from high-voltage motor supply lines.\u003c\/li\u003e\n\u003cli\u003eVerify that field supply voltages stay within the 0 to 132 VAC operating envelope to prevent overvoltage damage to channel optocouplers.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43724896927834,"sku":"IC694MDL250","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694MDL250.png?v=1784881474","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-ic694mdl250-pacsystem-rx3i-discrete-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}