{"product_id":"ge-fanuc-ic695psa140-pacsystem-rx3i-multi-purpose-power-supply","title":"GE Fanuc IC695PSA140 PACSystem RX3i Multi-Purpose Power Supply","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695PSA140\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695PSA140\u003c\/strong\u003e Multi-Purpose Power Supply, operates as a dedicated hardware component for internal backplane power distribution and load-sharing execution within PACSystem RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695PSA140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ As specified on hardware label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.25 lbs (0.57 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard single RX3i power supply slot footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput Power: 70 W maximum; Output Capacity: 40 W total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC (120\/240 VAC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 300 VDC (125 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rails\u003c\/td\u003e\n\u003ctd\u003e+5.1 VDC (30 W max, limited to 7 A); +3.3 VDC (limited to 10 A); +24 VDC relay output (30 W max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Support\u003c\/td\u003e\n\u003ctd\u003eUniversal Backplane only (IC695 catalog series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eSupports load sharing and N+1 redundancy (up to 4 modules per rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic LEDs\u003c\/td\u003e\n\u003ctd\u003ePower, P\/S Fault, Overtemp, Overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Current Limit\u003c\/td\u003e\n\u003ctd\u003e6 A per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA140 supplies stable regulated voltage rails directly across the RX3i Universal Backplane structure, accommodating high-speed logic execution without degrading backplane bus communication velocity. Onboard hardware overcurrent protection limits the +5.1 VDC output to 7 A and the +3.3 VDC output to 10 A, while an internal input line fusible link prevents destructive fault propagation across connected CPU and I\/O modules. When configured in redundant configurations, a latched fault state isolates the failed supply to maintain uninterrupted processing and preserve firmware flash compatibility during hot-standby transitions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many IC695PSA140 power supply modules can be installed in a single RX3i backplane rack?\u003c\/p\u003e\n\u003cp\u003eA: Up to four IC695PSA140 modules can be installed in a single RX3i PACSystem Universal Backplane for load sharing and power redundancy applications.\u003c\/p\u003e\n\u003cp\u003eQ: How is a fault state cleared on the IC695PSA140 after an overload or overtemperature event latches the unit off?\u003c\/p\u003e\n\u003cp\u003eA: Once a fault condition latches the module into the OFF state, input AC or DC supply power must be power-cycled to reset the internal protection logic and resume normal operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that supply lines are de-energized before connecting AC (85 to 264 VAC) or DC (100 to 300 VDC) field wiring to the input terminal block.\u003c\/li\u003e\n\u003cli\u003eEnsure power wiring does not exceed the maximum rating of 6 A per terminal, using properly sized stranded copper conductors.\u003c\/li\u003e\n\u003cli\u003eInstall the IC695PSA140 exclusively into designated power supply slots on an RX3i Universal Backplane (IC695 series).\u003c\/li\u003e\n\u003cli\u003eMaintain proper cabinet ventilation to ensure ambient operating temperatures remain within limits, preventing overtemp trip latches.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43712967966810,"sku":"IC695PSA140","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC695PSA140.jpg?v=1784777611","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-ic695psa140-pacsystem-rx3i-multi-purpose-power-supply","provider":"SpareOil Automation","version":"1.0","type":"link"}