{"product_id":"ge-fanuc-is200acleh1acb-mark-vi-application-control-layer-module","title":"GE Fanuc IS200ACLEH1ACB Mark VI Application Control Layer Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IS200ACLEH1ACB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200ACLE\u003c\/strong\u003e Application Control Layer Module, operates as a dedicated hardware component for high-speed application execution, system coordination, and network interfacing within GE Mark VI control platforms. It processes control code algorithms, handles IONet communication cycles, and manages data exchange across the VME backplane architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ACLEH1ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE Fanuc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot VME board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane VME bus powered (+5 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eApplication Control Layer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Architecture\u003c\/td\u003e\n\u003ctd\u003eVMEbus interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eIONet \/ Ethernet network interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eOnboard diagnostic LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Deterministic Network Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe IS200ACLEH1ACB maintains local execution routines via onboard non-volatile memory, supporting full firmware flash compatibility for system updates deployed through the ControlST software environment. It coordinates real-time data flow across deterministic IONet communications and backplane buses, ensuring low-latency task execution and time synchronization across redundant controller configurations without interrupting active control loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is power supplied to the IS200ACLEH1ACB module?\u003c\/p\u003e\n\u003cp\u003eA: The board draws power directly from the Mark VI VME rack backplane power rails, utilizing +5 VDC and auxiliary VDC feeds provided by the rack power supply.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IS200ACLEH1ACB module be extracted while the VME rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: Module extraction during active operation is not recommended; power to the target VME rack slot must be isolated prior to insertion or removal to prevent backplane connector arcing and signal disruption.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module transmit hardware diagnostic states to the controller?\u003c\/p\u003e\n\u003cp\u003eA: Onboard status LEDs display real-time hardware status, while diagnostic routines continuously transmit fault flags and memory status codes to the master controller over the internal IONet interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize and lock out all power sources to the Mark VI VME rack enclosure before installing the board.\u003c\/li\u003e\n\u003cli\u003ePut on an electrostatic discharge (ESD) grounding wrist strap connected to cabinet ground before handling the card.\u003c\/li\u003e\n\u003cli\u003eAlign the module circuit card edges with the top and bottom card guides of the assigned VME slot.\u003c\/li\u003e\n\u003cli\u003eSlide the board smoothly into the rack until the rear multi-pin connectors contact the backplane header pins.\u003c\/li\u003e\n\u003cli\u003eEngage the top and bottom ejector handles to seat the connectors fully, then tighten the captive retaining screws.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43846535708762,"sku":"IS200ACLEH1ACB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IS200ACLEH1ACB.jpg?v=1786698380","url":"https:\/\/www.spareoil.com\/products\/ge-fanuc-is200acleh1acb-mark-vi-application-control-layer-module","provider":"SpareOil Automation","version":"1.0","type":"link"}