{"product_id":"ge-ic200alg263-versamax-analog-input-module","title":"GE IC200ALG263 VersaMax Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200ALG263\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200ALG263\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for single-ended voltage signal conversion and data acquisition within VersaMax I\/O platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG263\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ Fanuc (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lbs (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA maximum at 5 VDC from Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eVersaMax I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e15 single-ended channels (1 group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e-10 VDC to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e+\/- 15 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e100 kOhms minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e7.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous user input to logic; 1500 VAC user input to frame ground for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eNone (Group-to-group: None)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eOK LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane Bus Communication and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG263 interfaces with the VersaMax backplane bus to transfer 15 words of analog input data to the host CPU or network interface unit within a fixed 7.5 ms update window. Onboard analog-to-digital processing routines align with controller firmware flash compatibility standards, maintaining deterministic backplane bus communication velocity while executing automated diagnostic routines, including continuous self-test signal verification across the conversion path.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200ALG263 require an external power supply for backplane operation?\u003c\/p\u003e\n\u003cp\u003eA: No, backplane power for module operation is supplied directly via the 5 VDC backplane bus at a maximum draw of 150 mA. External power is only required to drive system field transceivers.\u003c\/p\u003e\n\u003cp\u003eQ: What action does the module take if internal analog-to-digital diagnostics fail?\u003c\/p\u003e\n\u003cp\u003eA: If the module detects inaccurate analog-to-digital conversion results for more than three consecutive scan cycles, it halts channel scanning and extinguishes the onboard OK LED.\u003c\/p\u003e\n\u003cp\u003eQ: What cable type is specified for signal connections on the IC200ALG263?\u003c\/p\u003e\n\u003cp\u003eA: Shielded twisted-pair (STP) cabling is specified for all 15 single-ended channel connections to minimize signal noise and interference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize the VersaMax I\/O backplane and field loops prior to inserting or removing the module from its carrier base.\u003c\/li\u003e\n\u003cli\u003eEnsure proper static discharge precautions are observed by wearing an ESD wrist strap connected to cabinet earth ground.\u003c\/li\u003e\n\u003cli\u003eSeat the module firmly into an approved terminal-style, compact terminal-style, or connector-style VersaMax I\/O carrier until locking tabs engage completely.\u003c\/li\u003e\n\u003cli\u003eRoute all -10 VDC to +10 VDC input wiring using shielded twisted-pair cables, keeping signal runs separated from high-voltage AC lines.\u003c\/li\u003e\n\u003cli\u003eTerminate overall cable shields at a single chassis ground point to prevent ground loops across unisolated single-ended channels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43833213911130,"sku":"IC200ALG263","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200ALG3281_1d58f8dc-961e-42da-a0ec-4cc9f2111747.jpg?v=1786523321","url":"https:\/\/www.spareoil.com\/products\/ge-ic200alg263-versamax-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}