{"product_id":"ge-ic200mdl331-versamax-isolated-ac-output-original","title":"GE IC200MDL331 VersaMax Isolated AC Output Original","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDL331\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides eight isolated channels of discrete AC output for the VersaMax PLC platform. Operating at a nominal 120VAC, each channel delivers up to 2.0 Amperes of current, making it ideal for driving heavy-duty industrial solenoids, motor starters, and large indicator lamps. We offer this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system operates with factory-certified switching precision and robust channel isolation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete AC (Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 (Individually Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 to 132 VAC (47–63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent per Channel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 A (Maximum) \/ 0.5 A (Minimum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Leakage Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 2 mA at 132 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current (5V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 mA (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e½ Cycle (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Snubber and MOV for each output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 VAC (1 minute) Channel-to-Channel \/ Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndividual Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200MDL331 isolates each of the eight outputs individually. This architecture allows the module to switch different AC phases or separate power sources within a single module, eliminating the need for multiple interposing relays or additional hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy-Duty Load Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile standard PLC outputs often struggle with high-current demands, this module supports 2.0 Amperes per point. It directly controls large inductive loads, reducing cabinet complexity and wiring costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Surge Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery output contains a built-in Snubber circuit and Metal Oxide Varistor (MOV). These components absorb transient voltage spikes generated by inductive switching, protecting both the module’s internal circuitry and the connected field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Logic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptical couplers separate the field-side AC voltage from the low-voltage PLC backplane logic. This provides up to 1500 VAC of protection, ensuring that field faults do not propagate to the CPU or other sensitive modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Diagnostic LEDs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual channel LEDs provide immediate visual confirmation of output status. An additional \"OK\" LED monitors module health, significantly accelerating troubleshooting during commissioning or maintenance cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the IC200MDL331 with DC loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This module utilizes triac-based switching designed specifically for AC circuits (85-132 VAC). Attempting to switch DC loads will result in the output failing to turn off once energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 0.5A minimum load requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTriacs require a minimum holding current to stay in the \"ON\" state. If your load (such as a small LED indicator) draws less than 0.5A, the output may flicker or fail to latch. In such cases, you must install a parallel bleeder resistor to increase the current draw.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws 85mA from the backplane for logic operation, but the power used to drive the loads must come from an external AC source (85-132 VAC) wired to the isolated terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does individual isolation help in a multi-phase system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause each channel is isolated from the others, you can wire Channel 1 to Phase A and Channel 2 to Phase B without causing a short circuit. This is highly effective for controlling motors or devices across different power legs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217770741850,"sku":"IC200MDL331","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/500._a205379f-2e2a-4155-b769-675df47b1be3.jpg?v=1776216208","url":"https:\/\/www.spareoil.com\/products\/ge-ic200mdl331-versamax-isolated-ac-output-original","provider":"SpareOil Automation","version":"1.0","type":"link"}