{"product_id":"ge-ic200pbi001-profibus-network-interface-12mbps-original","title":"GE IC200PBI001 PROFIBUS Network Interface 12Mbps Original","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200PBI001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the high-speed communication gateway for the VersaMax I\/O station within a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS-DP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetwork. This Network Interface Unit (NIU) enables a PROFIBUS Master to control remote VersaMax I\/O modules as a distributed slave station. It handles all data exchange between the PROFIBUS bus and the local I\/O modules, supporting up to 375 bytes of total data. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original in Factory Packing\u003c\/strong\u003e, ensuring immediate integration and long-term network stability for your automation architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS-DP (IEC 61158)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Rates\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.6 Kbaud to 12 Mbaud (Auto-Detected)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Address\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 to 125 (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e375 Bytes Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput\/Output Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 244 Bytes Input or 244 Bytes Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 8 modules per station (Up to 64 total via racks)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9-pin D-sub (Female)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Topology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLinear bus, terminated at both ends\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Bytes Standard PROFIBUS Diagnostics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5V @ 250 mA; 3.3V @ 10 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePWR, OK, FAULT, NETWORK, FORCE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Determinism:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200PBI001 supports the full PROFIBUS-DP speed range up to 12 Mbps. The auto-detection feature ensures the module synchronizes instantly with the master’s baud rate, reducing commissioning time and guaranteeing deterministic data exchange for time-critical processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLarge-Scale I\/O Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA single NIU station supports up to 8 I\/O modules locally and can expand to manage 64 modules across 8 racks using expansion cables. This scalability allows for high-density I\/O clusters at a single PROFIBUS node, optimizing network address usage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Linear Topology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for industrial environments, the module utilizes shielded twisted-pair cabling. It supports transmission distances from 100 to 1200 meters (depending on baud rate), allowing you to distribute I\/O across vast factory floor areas without signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstant Visual Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFive dedicated LEDs provide real-time feedback. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNetwork LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifically monitors PROFIBUS communication health, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFault\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLEDs allow technicians to distinguish between internal hardware issues and external network wiring faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Diagnostic Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module transmits 5 bytes of standard PROFIBUS diagnostic data. This feature enables the master controller to monitor the health of individual I\/O modules within the slave station, facilitating proactive maintenance and reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the PROFIBUS address on the IC200PBI001?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou set the station address (1–125) using the hardware rotary switches located on the module or through the PROFIBUS configuration software (GSD file). Ensure the address is unique on the segment to avoid network conflicts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module function as a PROFIBUS Master?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200PBI001 is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSlave-only\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edevice. It requires a PROFIBUS Master, such as a PLC with a PROFIBUS Master module or a dedicated PC interface card, to initiate data exchange.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 12Mbps speed require specific cabling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. To achieve 12 Mbps, you must use PROFIBUS-certified Type A shielded twisted-pair cable and ensure proper active termination at both physical ends of the linear bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support PROFIBUS-DPV1 acyclic communications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC200PBI001 primarily supports standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS-DP (V0)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor cyclic data exchange. For applications requiring DPV1 (acyclic parameters), verify your specific GSD file version and firmware compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218263507034,"sku":"IC200PBI001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/20._963f4d5d-58de-4782-b5f9-a9a3c577a1b4.jpg?v=1776223937","url":"https:\/\/www.spareoil.com\/products\/ge-ic200pbi001-profibus-network-interface-12mbps-original","provider":"SpareOil Automation","version":"1.0","type":"link"}