{"product_id":"ge-ic200udr120-versamax-micro-plc-module","title":"GE IC200UDR120 VersaMax Micro PLC Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200UDR120\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200UDR120\u003c\/strong\u003e VersaMax Micro PLC Module, operates as a dedicated hardware component for discrete logical processing and high-speed count accumulation within VersaMax PLC architectures. Powered by a primary line voltage of 100 to 240 VAC, the unit accepts 12 sink\/source 24 VDC digital inputs and controls 8 electromechanical relay outputs rated for 2 A per channel. Capable of handling high-speed inputs up to 100 kHz with real-time status display via LED indicators, the controller manages real-time discrete logic execution across local machine I\/O loops.\u003c\/p\u003e\n\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UDR120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax Micro Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current Limit\u003c\/td\u003e\n\u003ctd\u003e9.4 A max for 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e12 points (24 VDC, Positive\/Negative logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counter\u003c\/td\u003e\n\u003ctd\u003e100 kHz maximum frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e8 points (Normally-Open Relays)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e2 A maximum per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e5 to 30 VDC or 5 to 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Output Load\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Leakage Current\u003c\/td\u003e\n\u003ctd\u003e15 mA at 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Life Expectancy\u003c\/td\u003e\n\u003ctd\u003e20 Million operations (mechanical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual Status\u003c\/td\u003e\n\u003ctd\u003eOnboard LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Backplane Communication \u0026amp; Firmware Integrity\u003c\/h3\u003e\n\u003cp\u003eThe IC200UDR120 maintains deterministic loop timing while transmitting register values across Profinet or EtherNet\/IP bus networks via interface adapters. High-density I\/O integration enables the concurrent sampling of 100 kHz high-speed counter channels alongside standard 24 VDC discrete field inputs without introducing logic scan jitter. Firmware flash compatibility ensures program execution retention during AC line supply disruptions up to the maximum hold-up threshold, maintaining reliable output state retention.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the switching voltage range and maximum current load for the relay outputs on the IC200UDR120?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 8 electromechanical relay outputs supports load voltages from 5 to 30 VDC or 5 to 250 VAC, with a continuous load rating up to 2 A per channel and a required minimum load of 10 mA.\u003c\/p\u003e\n\n\u003cp\u003eQ: How are positive and negative logic input configurations wired on the 12 DC inputs?\u003c\/p\u003e\n\u003cp\u003eA: Input circuit polarity is determined by field terminal wiring. Sinking (positive logic) or sourcing (negative logic) is configured by connecting the input common terminal to the positive or return leg of the external 24 VDC loop supply.\u003c\/p\u003e\n\n\u003cp\u003eQ: What inrush current profile must be accounted for during AC power application?\u003c\/p\u003e\n\u003cp\u003eA: The AC power supply stage generates a peak inrush current up to 9.4 A for a duration of up to 20 ms upon initial energization at maximum line voltage.\u003c\/p\u003e\n\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Disconnection\u003c\/strong\u003e: Lock out primary 100-240 VAC power feeds and auxiliary relay output voltages prior to performing terminal wiring or mechanical installation.\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Mount the base unit onto a standard 35 mm DIN rail, verifying that the retaining mechanism securely latches. Ensure the rail is bonded directly to protective earth (PE).\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Wiring and Inrush Protection\u003c\/strong\u003e: Wire 100-240 VAC line power to the dedicated supply terminals using properly sized wire to handle the 9.4 A peak inrush current.\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Routing \u0026amp; Suppression\u003c\/strong\u003e: Isolate 24 VDC discrete input cables from high-voltage AC relay output circuits. Install inductive surge suppression devices (RC snubbers or flyback diodes) directly across inductive loads to preserve relay contact service life.\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Clearances\u003c\/strong\u003e: Allow a minimum vertical clearance of 50 mm above and below the module enclosure to maintain passive convection airflow across the operating temperature envelope.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43791694889050,"sku":"IC200UDR120","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200UDR120.png?v=1785986111","url":"https:\/\/www.spareoil.com\/products\/ge-ic200udr120-versamax-micro-plc-module","provider":"SpareOil Automation","version":"1.0","type":"link"}