{"product_id":"ge-ic220alg220-versapoint-analog-input-module","title":"GE IC220ALG220 VersaPoint Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC220ALG220\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC220ALG220\u003c\/strong\u003e VersaPoint Analog Input Module, operates as a dedicated hardware component for multi-range analog signal acquisition within VersaPoint I\/O platforms. The module interfaces two independent single-ended analog input channels, conditioning current and voltage field signals into digitized measurement formats for real-time PLC backplane processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC220ALG220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Standard Industrial Operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2 single-ended analog channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Resolution\u003c\/td\u003e\n\u003ctd\u003e15-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, -20 to +20 mA, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V, -10 to +10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter Limit Frequency\u003c\/td\u003e\n\u003ctd\u003e40 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Wiring Support\u003c\/td\u003e\n\u003ctd\u003e2-wire and 3-wire connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaPoint module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard VersaPoint module weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard VersaPoint local bus power draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe internal conversion architecture digitizes field variables at 15-bit resolution and transfers data across local backplane buses to preserve cycle timing across EtherNet\/IP and Profinet deterministic networks. High-density I\/O scaling allows flexible mixing of analog and discrete expansion nodes on a single rail segment. Firmware flash compatibility ensures synchronized parameter assignment, channel processing, and register alignment between the expansion module and host controllers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the two input channels on the IC220ALG220 be configured with different signal ranges?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each of the two analog channels supports independent range selection, allowing one channel to read 4 to 20 mA current loops while the second reads a -10 to +10 V voltage signal.\u003c\/p\u003e\n\u003cp\u003eQ: What is the hardware analog-to-digital resolution supported by the module?\u003c\/p\u003e\n\u003cp\u003eA: The module operates with 15-bit analog resolution, which remains consistent across both standard numerical representation formats and all measuring ranges.\u003c\/p\u003e\n\u003cp\u003eQ: What sensor wiring schemes are supported by the input terminal connections?\u003c\/p\u003e\n\u003cp\u003eA: The module accepts direct termination for both 2-wire transmitter loops and 3-wire sensor configurations without external signal conditioning.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower Disconnection: Isolate local terminal block power and VersaPoint local bus power before attaching or removing the module from the mounting DIN rail.\u003c\/li\u003e\n\u003cli\u003eSignal Cable Shielding: Terminate twisted-pair signal cable shielding directly at the designated local bus ground reference point to prevent high-frequency noise from corrupting 15-bit conversion values.\u003c\/li\u003e\n\u003cli\u003eSeparation of Field Wiring: Route low-level analog input cables in dedicated cable trays separated from high-voltage AC conductors and drive output lines.\u003c\/li\u003e\n\u003cli\u003eFilter Considerations: Account for the internal 40 Hz low-pass hardware filter response limit when programming fast-transient analog feedback loops in host logic.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43796873805914,"sku":"IC220ALG220","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC220ALG220.jpg?v=1786090474","url":"https:\/\/www.spareoil.com\/products\/ge-ic220alg220-versapoint-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}