{"product_id":"ge-ic670chs101-terminal-block-for-field-control-modules","title":"GE IC670CHS101 Terminal Block for Field Control Modules","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC670CHS101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the structural and electrical foundation for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed I\/O family. This terminal block mounting base provides the critical interface between physical field-side wiring and the logic-side communication bus. It hosts various IC670 series I\/O modules, enabling seamless data exchange with the Bus Interface Unit (BIU). We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system infrastructure benefits from pristine electrical contacts and maximum mechanical durability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (General Electric \/ Emerson)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC670CHS101\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eField Control \/ Genius I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Block Base Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBarrier-Style Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot Insertion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupported (Module replacement under power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAll GE IC670 series I\/O modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN-rail or Panel mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 mm x 100 mm x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL, CSA, CE Certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.50 kg (1.09 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePermanent Field Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField wires connect directly to the IC670CHS101 base rather than the I\/O module. This architecture permits technicians to perform module maintenance or system upgrades without disturbing field-side wiring, eliminating the risk of re-wiring errors and reducing commissioning time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot Insertion Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal backplane design supports hot-swapping. You can replace I\/O modules while the station remains powered and the rest of the network remains operational. This feature drastically lowers Mean Time to Repair (MTTR) in mission-critical processes where downtime is prohibited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Barrier Terminal Blocks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-vibration environments often compromise standard push-in connectors. The IC670CHS101 utilizes heavy-duty screw-type barrier terminals. These provide a secure mechanical grip and prevent accidental short circuits between adjacent channels, even in high-vibration applications like mining or heavy manufacturing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Logic Bus:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach base contains a segment of the local backplane. When you link multiple IC670CHS101 bases together, they form a continuous path for data and power. This modularity allows for the rapid expansion of I\/O points without requiring custom backplane cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal and Environmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit maintains electrical integrity across a 0°C to +60°C temperature range. Its specialized housing material resists the industrial pollutants and thermal stresses common on modern factory floors, ensuring a multi-decade operational lifespan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC670CHS101 be used with both Analog and Digital IC670 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The IC670CHS101 provides a universal mounting and bus interface that supports the entire range of IC670 series modules, including discrete inputs, discrete outputs, and analog signal processors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need special tools for mounting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe base features a standard snap-on provision for 35mm DIN-rails, requiring no tools for rail attachment. For panel mounting, standard screw holes are provided to ensure a rigid installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"Hot Insertion\" feature protect the system logic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe base includes specialized circuitry that manages power sequencing during module insertion. It ensures that the I\/O module initializes correctly before the Bus Interface Unit (BIU) begins data polling, preventing logic bus \"noise\" or communication hangs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy should I avoid using \"Pull-Out\" or used bases for my PLC system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMounting bases house the primary terminal screws and internal bus connectors. Used units often suffer from stripped screw threads or oxidized bus pins, which cause intermittent signal loss and \"phantom\" faults. Only a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIC670CHS101 guarantees the low-impedance connections required for reliable distributed I\/O communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870842982490,"sku":"IC670CHS101","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/88.1_6c62d795-dee1-4fe7-9821-2fd4d6681e0b.jpg?v=1776330185","url":"https:\/\/www.spareoil.com\/products\/ge-ic670chs101-terminal-block-for-field-control-modules","provider":"SpareOil Automation","version":"1.0","type":"link"}