{"product_id":"ge-ic693mdl753-series-90-30-digital-output-module","title":"GE IC693MDL753 Series 90-30 Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC693MDL753\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693MDL753\u003c\/strong\u003e discrete output module, operates as a dedicated hardware component for solid-state switching of external direct current loads within Series 90-30 programmable logic controller architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL753\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFactory standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg (0.56 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot chassis occupancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (Standard industrial environment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e260 mA at 5 VDC (from backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e32 output points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Grouping\u003c\/td\u003e\n\u003ctd\u003e4 isolated groups (8 points per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e12 - 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10.2 - 28.8 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating per Group\u003c\/td\u003e\n\u003ctd\u003e4.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup Common Pin Rating\u003c\/td\u003e\n\u003ctd\u003e3.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current Limit\u003c\/td\u003e\n\u003ctd\u003e5.4 A maximum for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e0.3 VDC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e1.0 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (On \/ Off)\u003c\/td\u003e\n\u003ctd\u003e0.5 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic-to-Field Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC (Optical via opto-couplers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup-to-Group Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Cable Assembly\u003c\/td\u003e\n\u003ctd\u003eIC693CBL315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Architecture and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the Series 90-30 parallel backplane bus, utilizing high-density logic layout to compress 32 independent positive-logic points into a single mechanical chassis slot. To maintain bus signal integrity and prevent velocity degradation across adjacent modules, the logic subsystem limits its current draw on the 5 VDC rail to 260 mA. Optical isolation components isolate the host processor execution cycle from external field transients up to 1500 VDC, preventing electromagnetic interference from disrupting internal backplane registers or interrupting discrete deterministic updating networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping while the PLC backplane is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. The Series 90-30 backplane architecture does not support live insertion or removal. Power to the rack must be entirely disconnected before inserting or removing the module to prevent electrical damage to the logic circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: What is the deterministic state of the outputs if the CPU stops executing?\u003c\/p\u003e\n\u003cp\u003eA: If the host CPU enters a stop state or communication over the backplane bus is lost, internal safety logic forces all 32 output channels to transition immediately to the OFF state.\u003c\/p\u003e\n\u003cp\u003eQ: Can distinct external voltages be applied to different output groups on the same module?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 32 channels are segmented into four isolated groups of eight points. Each group features its own independent common return pin, allowing different external DC power sources within the 10.2 to 28.8 VDC operating envelope to be wired to separate groups.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize the PLC power supply module and all external field wiring loops before performing installation tasks.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the top and bottom chassis guides in any available slot except slot 1, which is reserved exclusively for the CPU or specialized modules.\u003c\/li\u003e\n\u003cli\u003ePress the module firmly into the slot until the plastic retention hooks click into place on the chassis rail.\u003c\/li\u003e\n\u003cli\u003eTerminate field wiring using the two front-mounted 24-pin male connectors. Utilize pre-assembled IC693CBL315 cable units to ensure proper terminal alignment.\u003c\/li\u003e\n\u003cli\u003eRoute DC field signal wiring through separate wiring ducts from high-voltage AC power lines to mitigate inductive and capacitive cross-talk.\u003c\/li\u003e\n\u003cli\u003eInstall external flyback diodes across inductive DC loads (such as relay coils or solenoids) to suppress back-EMF voltage transients during switching transitions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43616357908570,"sku":"IC693MDL753","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693MDL753.png?v=1783476507","url":"https:\/\/www.spareoil.com\/products\/ge-ic693mdl753-series-90-30-digital-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}