{"product_id":"ge-ic694mdl340-pacsystems-rx3i-discrete-output-module","title":"GE IC694MDL340 PACSystems RX3i Discrete Output Module","description":"\u003cp\u003eConfigured for solid-state switching of alternating current field loads within PACSystems RX3i networks, the \u003cstrong\u003eGE IC694MDL340\u003c\/strong\u003e (\u003cstrong\u003eIC694MDL340\u003c\/strong\u003e Discrete Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694MDL340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFactory standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot chassis occupancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e315 mA maximum at 5 VDC (from backplane bus when all channels are energized)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e16 output points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Grouping\u003c\/td\u003e\n\u003ctd\u003e2 isolated groups (8 points per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 - 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating per Group\u003c\/td\u003e\n\u003ctd\u003e3.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e20 A for 1 cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1.5 VAC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e2 mA maximum at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (On \/ Off)\u003c\/td\u003e\n\u003ctd\u003eOn: 1 ms maximum \/ Off: 1\/2 cycle maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous (group-to-group), 1500 VAC for 1 minute (field-to-logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Fuses\u003c\/td\u003e\n\u003ctd\u003e2 pre-installed fuses (3 A, part number 44A724627-111, 1 per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module handles discrete actuation profiles by interfacing 16 AC output channels directly over the PACSystems RX3i parallel backplane. Internal gate arrays route command blocks from the primary controller, drawing a peak of 315 mA from the 5 VDC bus rail. To prevent high-frequency line harmonics from degrading backplane bus communication velocity during maximum I\/O density scaling, each circuit group incorporates an integrated RC snubber network. Optical isolation components provide a continuous 250 VAC group-to-group barrier and a 1500 VAC field-to-logic shield, suppressing electrical transients from high-inrush inductive and incandescent loads before they affect backplane data frames.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the separate output groups on this module be sourced from different AC power phases?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Because the 16 channels are divided into two distinct groups of eight with an independent common return and 250 VAC continuous insulation for each group, they can be connected to separate AC power supply phases or derived from a uniform single-phase source.\u003c\/p\u003e\n\u003cp\u003eQ: What is the mechanical action required if an internal circuit fault causes a fuse to fail?\u003c\/p\u003e\n\u003cp\u003eA: The module is equipped with a dedicated front panel \"F\" LED indicator to register a cleared condition. The user must isolate power, pull the module from the slot, and replace the corresponding internal 3 A fuse using the approved replacement part number 44A724627-111.\u003c\/p\u003e\n\u003cp\u003eQ: Does this hardware support live insertion and extraction within the active chassis?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The PACSystems RX3i backplane protocol allows for hot-swap execution of I\/O modules, provided the specific safety steps, grounding procedures, and slot constraints outlined in the system controller firmware manual are maintained.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize all external user-supplied AC power loops connected to the output terminals prior to handling the component.\u003c\/li\u003e\n\u003cli\u003eAlign the module chassis with the upper and lower guide slots of the designated I\/O slot in the active PACSystems RX3i baseplate.\u003c\/li\u003e\n\u003cli\u003eSlide the module firmly backward until the top and bottom edge-retention levers click and lock into the chassis rail tabs.\u003c\/li\u003e\n\u003cli\u003eVerify that each output group is protected by a 3 A external circuit breaker or the correct internal fuse rating to manage high inrush currents.\u003c\/li\u003e\n\u003cli\u003eRoute the AC field load wiring through separate wire trays isolated from low-voltage DC measurement or communication signaling cables by at least 30 cm.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43616480624730,"sku":"IC694MDL340","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694MDL340.png?v=1783480438","url":"https:\/\/www.spareoil.com\/products\/ge-ic694mdl340-pacsystems-rx3i-discrete-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}