{"product_id":"ge-ic694mdl634-rx3i-pacsystem-discrete-input-module","title":"GE IC694MDL634 RX3i PACSystem Discrete Input Module","description":"\u003cp\u003eConfigured for discrete signal sensing in RX3i PACSystem platforms, the \u003cstrong\u003eGE IC694MDL634\u003c\/strong\u003e (\u003cstrong\u003eIC694MDL634\u003c\/strong\u003e Discrete Input Module) provides direct physical\/electrical execution. The module captures field inputs across 8 points arranged in 1 group, operating with 24 VDC positive or negative logic to evaluate signal states from switches, pushbuttons, and proximity sensors.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694MDL634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eRX3i PACSystem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8 points (1 group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (positive or negative logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e11.5 to 30 VDC \/ 3.2 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage \/ Current\u003c\/td\u003e\n\u003ctd\u003e0 to 5 VDC \/ 1.1 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e7 ms typical (On\/Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e45 mA at 5 VDC bus; 62 mA at 24 VDC user supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e8 green LEDs (points 1 to 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration \/ Shock\u003c\/td\u003e\n\u003ctd\u003e1.0 g at 57-500 Hz \/ 15 G, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot RX3i module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Interfacing and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL634 interfaces with the RX3i backplane bus to transfer digitized input state tables directly to the controller CPU. Utilizing high backplane bus communication velocity, discrete input updates are processed deterministically within each cycle. Onboard firmware flash compatibility maintains signal timing alignment when scaling I\/O density across multi-rack RX3i expansion configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane and external power requirements for the IC694MDL634?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 45 mA from the internal 5 VDC backplane bus and 62 mA from an external 24 VDC power supply.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC694MDL634 accept both sinking and sourcing field inputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 8 input points support both positive logic (sinking) and negative logic (sourcing) configurations at 24 VDC nominal.\u003c\/p\u003e\n\u003cp\u003eQ: What are the physical on\/off threshold limits for the input signals?\u003c\/p\u003e\n\u003cp\u003eA: An input point registers an On state between 11.5 and 30 VDC (3.2 mA min) and an Off state between 0 and 5 VDC (1.1 mA max).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate main backplane power and external 24 VDC field supplies before inserting or removing the module from the baseplate slot.\u003c\/li\u003e\n\u003cli\u003eFasten an ESD grounding wrist strap to an unpainted grounded metal frame inside the enclosure prior to handling the module assembly.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing with the RX3i baseplate slot guides and press firmly until the rear connector seats and the latching mechanism engages.\u003c\/li\u003e\n\u003cli\u003eWire input field devices to the terminal block, ensuring proper common wire configuration for positive or negative logic operation.\u003c\/li\u003e\n\u003cli\u003eRestore power and verify that the front-panel status LEDs correctly indicate channel input states upon actuation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43787835834458,"sku":"IC694MDL634","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694MDL634.jpg?v=1785922803","url":"https:\/\/www.spareoil.com\/products\/ge-ic694mdl634-rx3i-pacsystem-discrete-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}