{"product_id":"ge-ic697acc701-series-90-70-cpu-memory-backup-battery","title":"GE IC697ACC701 Series 90-70 CPU Memory Backup Battery","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc IC697ACC701\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the critical safeguard for volatile memory within the Series 90-70 PLC platform. This 3.0V Lithium battery prevents the loss of user programs, configuration data, and register values during power interruptions. It provides the necessary pulse current to maintain high-speed CMOS RAM in both CPU and Programmable Coprocessor Modules (PCM). We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring maximum shelf life and reliable field performance in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLithium Backup Battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc Series 90-70 PLC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePulse Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChemistry\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLithium Manganese Dioxide\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCPU and PCM (Quantity 2 required for redundancy in some racks)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg (Net Weight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Integrity Assurance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC697ACC701 maintains the \"Logic State\" of your controller during total power loss. It sustains the CMOS RAM, ensuring the PLC resumes operation instantly upon power restoration without requiring a program reload.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Pulse Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard consumer batteries, this industrial-grade cell handles 250mA pulse currents. This high discharge rate supports the instantaneous power requirements of Series 90-70 memory circuits during the transition from line power to battery power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Shelf Life:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe high-purity lithium chemistry offers a low self-discharge rate. This allows for long-term storage and provides years of reliable service while installed in a standby capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe battery features a specialized connector designed for the Series 90-70 battery housing. This prevents polarity errors and allows for rapid \"hot-swapping\" while the PLC remains powered, avoiding any data loss during the replacement process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Resistant:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe robust internal construction withstands the constant mechanical vibrations typical of heavy manufacturing and utility control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. How often should I replace the IC697ACC701 battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnder standard operating temperatures, you should replace the battery every 12 to 24 months as part of preventative maintenance. High ambient temperatures may shorten this interval. Always replace the battery when the \"BATT\" LED on the CPU module illuminates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Can I replace this battery while the PLC is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. To avoid losing your program and register data, we recommend replacing the battery while the PLC power supply is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eON\u003c\/strong\u003e. This ensures the backplane provides logic power to the RAM while you swap the cells.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Does this battery work for Series 90-30 PLCs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC697ACC701 is specifically sized and rated for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSeries 90-70\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(IC697) platform. Series 90-30 (IC693) systems typically use the IC693ACC301 battery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Why does my rack require two IC697ACC701 batteries?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCertain Series 90-70 configurations, particularly those using Programmable Coprocessor Modules (PCM) alongside the CPU, require two batteries to support independent memory registers across different slots. Check your specific module documentation for the required quantity.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43344498491482,"sku":"IC697ACC701","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/545_55df84f0-e8e1-4f0c-8feb-ba7834d2d1cd.jpg?v=1778463597","url":"https:\/\/www.spareoil.com\/products\/ge-ic697acc701-series-90-70-cpu-memory-backup-battery","provider":"SpareOil Automation","version":"1.0","type":"link"}