{"product_id":"ge-is200trlys1bgg-mark-vi-discrete-relay-termination-board","title":"GE IS200TRLYS1BGG Mark VI Discrete Relay Termination Board","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200TRLYS1BGG\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200TRLY\u003c\/strong\u003e Discrete Relay Termination Board, operates as a dedicated hardware component for switching discrete control signals and executing relay contact outputs within GE Mark VI Speedtronic platforms. Equipped with plug-in magnetic relays using Form C contacts, this specific board revision includes onboard diagnostic circuitry configured for coil current evaluation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TRLYS1BGG (IS200TRLY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eCircuit Dependent (Supports 120\/240 VAC Power Sources)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003ePlug-in Magnetic Relays with Form C Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Function\u003c\/td\u003e\n\u003ctd\u003eCoil Current Diagnostics (S1BGG Revision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 Barrier-type Screw Terminal Strips (Numbered Terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Connectivity\u003c\/td\u003e\n\u003ctd\u003e4 D-shell Connectors, 3 Three-pin Plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePassive Components\u003c\/td\u003e\n\u003ctd\u003eFuses, Variable Resistors, Diodes, Capacitors, Integrated Circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane Bus Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IS200TRLYS1BGG processes discrete relay switching operations while providing fast channel feedback to the controller pack via high-density D-shell cabling interfaces. Operating without latency on the backplane bus communication velocity loop, the board transmits real-time coil current diagnostic status to verify solenoid and interlock execution. Full firmware flash compatibility within the Mark VI I\/O processor layer allows continuous line monitoring and dynamic state reporting across multi-channel I\/O density scaling configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary operational distinction between the IS200TRLYS1BGG and the TRLYH1C revision?\u003c\/p\u003e\n\u003cp\u003eA: The IS200TRLYS1BGG revision is equipped with diagnostic circuitry for relay coil current monitoring, whereas the TRLYH1C revision is configured specifically for contact voltage diagnostics.\u003c\/p\u003e\n\u003cp\u003eQ: How are field wiring connections landed on the IS200TRLYS1BGG?\u003c\/p\u003e\n\u003cp\u003eA: Field control lines connect directly to the two numbered barrier-type screw terminal strips positioned along the outer edge of the board.\u003c\/p\u003e\n\u003cp\u003eQ: Can individual relays be serviced or replaced on the board?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the board utilizes plug-in magnetic relays with Form C contacts, allowing individual relay units to be replaced without desoldering components from the printed circuit board.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all primary power supplies and field contact power sources (including 120\/240 VAC control loops) before servicing or installing the board.\u003c\/li\u003e\n\u003cli\u003eWear an ESD grounding wrist strap attached to a bare metal cabinet grounding point during module handling.\u003c\/li\u003e\n\u003cli\u003eSecure the terminal board firmly to the cabinet mounting plate using all designated screws to ensure chassis earth continuity.\u003c\/li\u003e\n\u003cli\u003eRoute high-voltage AC output relay lines away from low-voltage DC communication cables to prevent electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eVerify that all multi-pin D-shell connectors are fully seated and secured with their mechanical retention screws prior to reapplying power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43859612860506,"sku":"IS200TRLYS1BGG","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IS200TRLYS1BGG.png?v=1787021287","url":"https:\/\/www.spareoil.com\/products\/ge-is200trlys1bgg-mark-vi-discrete-relay-termination-board","provider":"SpareOil Automation","version":"1.0","type":"link"}