{"product_id":"general-electric-ds200dtbcg1a-mark-v-contact-output-termination-module","title":"General Electric DS200DTBCG1A Mark V Contact Output Termination Module","description":"\u003cp\u003eThe \u003cstrong\u003eGeneral Electric DS200DTBCG1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200DTBC\u003c\/strong\u003e Contact Output Termination Module, operates as a dedicated hardware component for relay contact output signal termination and solenoid power routing within Mark V Speedtronic Turbine Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS200DTBCG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard PCB weight (~0.65 kg \/ 1.43 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.00 in x 11.50 in (76.2 mm x 292.1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBus input scaled per terminal and relay load configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDTBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Revision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRevision A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCB Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 terminal blocks with terminals for up to 220 signal wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBayonet Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 3-wire bayonet connectors, 1 2-wire bayonet connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Signal Connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJS1 through JS8 TCRA board relay signal headers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJ8 TCPD board solenoid power, J15\/J16 125 VDC power headers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Customization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 onboard configuration jumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eConfigured to interface with the Speedtronic Mark V control core, the module routes high-density relay contact signals across deterministic control networks. Onboard power distribution headers (J15 and J16) couple with internal control paths to manage contact output switching cycles (specifically contact outputs #16, #17, and #18). Maintained trace spacing and protective board coatings preserve signal integrity during continuous high-density I\/O scanning while firmware flash compatibility ensures synchronized relay execution across connected primary processors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do connectors J15 and J16 function on the DS200DTBCG1A terminal board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: Connectors J15 and J16 route 125 VDC power through the module and typically jumper together to drive contact outputs #16, #17, and #18 within the Mark V automated drive assembly.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What wiring separation rules must be followed when terminating signal leads to the terminal blocks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: Low-voltage signal conductors terminating at TB1 and TB2 must be physically segregated from high-power supply cables to prevent inductive and capacitive noise coupling.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What interface connects the DS200DTBCG1A module to the TCRA relay board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: Relay control signals are routed between the DS200DTBCG1A module and the TCRA relay board using headers JS1 through JS8.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e De-energize all 125 VDC power feeds and field solenoid power lines to the cabinet before servicing board connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Wear a grounded ESD wrist strap before handling the PCB to prevent static discharge to exposed component leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Mounting:\u003c\/strong\u003e Mount the 3.00 in x 11.50 in board securely inside the designated Mark V enclosure slots, ensuring clear air flow from bottom cabinet vents to top exhaust vents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Wire Routing:\u003c\/strong\u003e Dress all 220 potential signal wires cleanly into terminal blocks TB1 and TB2. Avoid routing signal wires in parallel with AC power cables; cross AC power lines at 90 deg angles if intersection is unavoidable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Position Audit:\u003c\/strong\u003e Verify that all 10 onboard configuration jumpers match the system field wiring diagram prior to applying system power.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43904488505434,"sku":"DS200DTBCG1A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/DS200DTBCG1AAA_db66115c-cae8-4a18-bdc7-086d4774264e.png?v=1787650233","url":"https:\/\/www.spareoil.com\/products\/general-electric-ds200dtbcg1a-mark-v-contact-output-termination-module","provider":"SpareOil Automation","version":"1.0","type":"link"}