{"product_id":"hima-982200442-f-3dio20-802-distributed-i-o-block","title":"HIMA 982200442 F 3DIO20\/802 Distributed I\/O Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe HIMA F3DIO20\/802 (Factory Part Number: 982200442) operates as a high-integrity, 20-channel mixed digital remote input\/output module engineered for HIMA HIMatrix and HIMax safety instrumented systems (SIS). This compact, distributed automation component combines 12 safety-rated digital inputs and 8 high-capacity digital transistor outputs within a single physical housing. By consolidating bidirectional discrete channels onto a single node, the module reduces marshalling panel space and simplifies field loop wiring. Control engineers deploy this remote I\/O unit across field networks to simultaneously read status sensors and actuate critical final control elements like emergency shutdown (ESD) valves, motor contactors, and fire suppression alarms.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF3DIO20\/802 (F3 DIO 20\/8 02)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e982200442\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRemote Mixed Digital Input \/ Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA HIMatrix Platforms and HIMax Safety Frameworks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Channel Density\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 independent safety-rated channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channel Allocation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 discrete digital inputs (24 VDC typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channel Allocation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 discrete digital outputs (24 VDC solid-state transistor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Output Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2.0 Amps continuous driving capacity per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 to 30 VDC continuous input monitoring range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Response Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFast-acting processing loop execution under 5 milliseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Response Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-latency switching execution under 10 milliseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGalvanic Isolation Barrier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull physical isolation between channels and internal system bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOnboard Diagnostic Suite\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLine monitoring, short-circuit detection, front-panel LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC nominal operating input (plus\/minus 20 percent window)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Power Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Watts internal power consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Component Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2 cm x 12.4 cm x 12.6 cm (W x H x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Component Mass\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg (0.66 lbs) raw module state\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Assembly Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg (3.31 lbs) including specialized transit packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Envelope\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +60 degrees Celsius continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 degrees Celsius dry ambient\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Safety Standards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCertified to IEC 61508 SIL 3 application loops via TUeV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Protection Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eComplete EMC compliance and short-circuit resistant build\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcurement Supply Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 percent Brand New and Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFactory Warranty Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Months from purchase date\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eHigh-Density Mixed I\/O Architecture Drastically Shrinks Footprint\u003c\/h3\u003e\n\u003cp\u003eTraditional distributed safety architectures require separate dedicated input racks and output modules, which rapidly fills up limited control cabinet space on offshore platforms and remote pumping stations. The F3DIO20\/802 solves this packaging problem by integrating a 12-input and 8-output matrix into a slim 2.2 cm wide enclosure. This high concentration of mixed channels allows field teams to manage local loops entirely from a single compact DIN-rail mounting location, cutting total module purchase expenses and reducing cabinet footprint requirements.\u003c\/p\u003e\n\u003ch3\u003eHeavy-Duty 2A Transistor Outputs Drive Inductive Elements Directly\u003c\/h3\u003e\n\u003cp\u003eStandard low-power PLC outputs often require external interposing relays to handle the high current demands of large industrial solenoids and actuators. The F3DIO20\/802 incorporates rugged solid-state transistor outputs that supply up to 2.0 Amps of continuous current per channel. This heavy-duty current delivery allows the module to actuate large field-mounted shutdown valves and magnetic motor switches directly from the card edge, removing secondary failure points and lowering hardware integration costs.\u003c\/p\u003e\n\u003ch3\u003eContinuous Line Monitoring Stops Intermittent Loop Faults In Stride\u003c\/h3\u003e\n\u003cp\u003eCorroded terminals or pinched copper wires create intermittent field faults that jeopardize safety loop readiness. The F3DIO20\/802 runs active background line-monitoring diagnostics that continuously test field lines for open circuits and dead short-circuits. If a field wire breaks or experiences an overcurrent spike, the module isolates that specific channel instantly to preserve overall board health, illuminates a targeted diagnostic faceplate LED, and passes the error code to the central safety controller to trigger immediate maintenance alerts.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the HIMA F3DIO20\/802 support live component replacement while the plant runs?\u003c\/p\u003e\n\u003cp\u003eYes. The F3DIO20\/802 supports hot-swap maintenance procedures when deployed within a redundant or properly bypassed HIMA safety network configuration. Maintenance personnel can safely extract a faulty module from its slot and insert a brand new, factory-original unit without dropping power to the adjacent nodes or interrupting the continuous processing communication on the main network bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to the 8 solid-state outputs if the main power source fails?\u003c\/p\u003e\n\u003cp\u003eThe F3DIO20\/802 utilizes fail-safe de-energization logic. If the main 24 VDC power supply suffers a blackout or dips below the allowable 18 VDC operating threshold, the internal biasing circuits drop out immediately, causing all 8 transistor outputs to turn off instantly. This de-energized design forces downstream safety elements into their predefined zero-energy fail-safe states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should field technicians manage the high inductive kickback from large solenoid valves?\u003c\/p\u003e\n\u003cp\u003eWhile the module incorporates internal solid-state protection mechanisms, driving heavy inductive field devices can cause localized heat buildup during rapid cycling. Field engineers should install external flywheel diodes across DC inductive loads or surge suppressors across AC elements. This protective design absorbs reverse electromotive force (EMF) voltage spikes at the field source, extending the service life of the module transistor output stages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43399581991002,"sku":"F3DIO20\/802","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/199._824f660f-39dc-4070-84c6-ce35298ade8b.jpg?v=1779329192","url":"https:\/\/www.spareoil.com\/products\/hima-982200442-f-3dio20-802-distributed-i-o-block","provider":"SpareOil Automation","version":"1.0","type":"link"}