{"product_id":"hima-f-3300-hiquad-safety-controller-cpu-modules","title":"HIMA F 3300 HIQuad Safety Controller CPU Modules","description":"\u003ch2\u003eHIMA F3300 Safety Controller CPU Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for executing safety application logic in H41q, H51q, and HIQuad safety platforms, the \u003cstrong\u003eHIMA F3300\u003c\/strong\u003e (\u003cstrong\u003eF3300\u003c\/strong\u003e Safety Controller CPU Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e172 mm x 110 mm x 41 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eCentral Processing Unit (CPU) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eDual clock-synchronized microprocessors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Cycle Time\u003c\/td\u003e\n\u003ctd\u003eAs low as 500 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-Board Memory\u003c\/td\u003e\n\u003ctd\u003eUp to 16 MB for application code, data, and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e16 digital inputs (24 VDC typical, ~8 mA per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field channels and system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Connectivity\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS, PROFINET, and Modbus communication protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety Rating\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 SIL3 certified by TUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundancy and Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe F3300 module incorporates dual clock-synchronized microprocessors to deliver deterministic processing across safety-critical loops. Operating under a fail-safe state execution model, the internal diagnostic subsystem continuously monitors central processing routines and cross-checks input channels for line breaks or short circuits. If hardware faults exceed defined safety thresholds, the module immediately forces outputs into a predefined de-energized safe state.\u003c\/p\u003e\n\u003cp\u003eFurthermore, integrated galvanic isolation prevents electrical surges from propagating between field-side field wiring and internal bus logic. When engineers integrate the F3300 within redundant architecture configurations, the module coordinates fault detection without interrupting active logic solver execution, preserving SIL3 safety integrity across the process network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the F3300 enforce fail-safe execution during internal processor clock discrepancies?\u003c\/p\u003e\n\u003cp\u003eA: Dual clock-synchronized microprocessors continuously compare instruction execution steps. If hardware voting logic detects an unrecoverable mismatch between the processors, internal circuitry immediately trips the system into its fail-safe state.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel-to-bus galvanic isolation protect the F3300 system architecture?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic isolation electrically separates the 24 VDC field input signals from the internal system backplane. Consequently, high-voltage transients or ground loops occurring on field wiring cannot penetrate or damage the internal processor architecture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstallers must mount the F3300 module onto a standard DIN rail or enclosure rack within an IP20-rated enclosure. Before inserting the unit into the system chassis, field engineers must verify that input power supplies maintain a clean 24 VDC nominal voltage.\u003c\/p\u003e\n\u003cp\u003eRoute signal lines separately from high-voltage AC lines to prevent inductive coupling. Connect field wiring to dedicated terminal strips while ensuring that line monitoring circuits are correctly configured for sensor inputs.\u003c\/p\u003e\n\u003cp\u003eSystem integrators must ground the enclosure rack chassis directly to a low-impedance master safety ground bus. Proper single-point grounding maximizes noise rejection across the 16 digital channels and prevents common-mode noise from disrupting backplane communications.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43782748897370,"sku":"F3300","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/221._0ec9d462-cbb9-46de-b362-31294b8adb02.jpg?v=1785814620","url":"https:\/\/www.spareoil.com\/products\/hima-f-3300-hiquad-safety-controller-cpu-modules","provider":"SpareOil Automation","version":"1.0","type":"link"}