{"product_id":"hima-f-7126-brand-new-ip66-emergency-shutdown-power-card","title":"HIMA F 7126 Brand New IP66 Emergency Shutdown Power Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe HIMA F7126 operates as a high-capacity, high-integrity power supply and safety controller module purpose-built for HIMA HIMax safety instrumented systems (SIS). This rugged component conditions incoming raw DC power into stabilized, regulated voltages to drive critical safety central processing units (CPUs) and input\/output (I\/O) modules across the system backplane. Plant engineers integrate this module within emergency shutdown (ESD) systems, burner management systems (BMS), and turbomachinery control networks to secure continuous logic power and prevent hazardous spurious trips.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturer: HIMA Paul Hildebrandt GmbH + Co KG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: F7126\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrder Code: 990000111\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Category: Power Supply \/ Safety Controller Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Integrity Level: IEC 61508 SIL3 \/ IEC 61511 Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Voltage Envelope: 18 to 35 VDC wide range input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrimary Regulated Output: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Primary Current Delivery: 40 Amperes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal Rated Power Capacity: 960 Watts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecondary Output Option: 5 VDC plus or minus 0.5 V at 10 Amperes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecondary Overcurrent Threshold: Approximately 13 Amperes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnergy Conversion Efficiency: Greater than or equal to 77 percent\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIngress Protection Level: IP66 sealed enclosure rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature Profile: -40 to +70 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpace Requirement: 8 TE backplane chassis slot width\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApproximate Physical Dimensions: 200 mm x 140 mm x 70 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNet Unit Mass: 3.0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEquipment Condition: 100% Brand New and Original in Factory Packing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eHigh-Availability Redundancy and True Live Hot-Swapping\u003c\/h3\u003e\n\u003cp\u003eThe module architecture supports parallel, redundant installation profiles across the HIMax chassis. If an internal hardware fault develops or the primary input feed drops out, the secondary paired module absorbs the full system electrical load instantaneously without causing voltage sags on the logic bus. Advanced diagnostic circuits signal the failure immediately, allowing operators to execute a live hot-swap replacement without powering down active safety controllers or interrupting active plant safety loops.\u003c\/p\u003e\n\u003ch3\u003eHeavy Industrial Environmental Ingress and Thermal Performance\u003c\/h3\u003e\n\u003cp\u003eUnlike standard commercial-grade power supplies that require clean, air-conditioned rack rooms, the F7126 features an IP66-rated cast housing. This robust physical structure locks out airborne moisture, corrosive chemical gases, and fine particulates typical of oil and gas processing facilities. Furthermore, the specialized component engineering maintains stable voltage output across an ultra-wide thermal range from -40 to +70 degrees Celsius, which eliminates the need for external heating elements or active cabinet cooling fans in remote, unstaffed installations.\u003c\/p\u003e\n\u003ch3\u003eIntelligent Load Distribution and System-Wide Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe onboard electronics integrate Ethernet, serial, and secure bus communication interfaces that pass real-time diagnostics directly to the main safety processor. The module continuously tracks input\/output voltage status, aggregate current draw, and internal component temperature profiles. This data flow allows predictive maintenance software to flag overload conditions or upstream supply decay before an actual system trip occurs.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use the HIMA F7126 as a standalone power supply for third-party automation equipment? No. HIMA engineers optimized the mechanical form factor, backplane connection contacts, and secure bus communication links specifically for the HIMax rack system. The module relies on the structural backplane to distribute power safely and cannot function as a standalone generic power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat load precautions must system integrators take when deploying the 40 Ampere output? System designers must calculate the total steady-state and inrush current draw of all connected safety controllers and I\/O modules to ensure the total continuous load remains below 40 Amperes. Exceeding the 40 Ampere ceiling triggers the internal thermal and overcurrent protection, forcing a safe shutdown of the module to prevent physical component damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the module handle voltage spikes or unstable input power in field setups? The wide input tolerance range (18 to 35 VDC) absorbs substantial industrial line fluctuations, sudden battery bank drops, or generator switching transients. The internal conditioning circuitry filters out high-voltage spikes and tightens the output to a clean, regulated 24 VDC to shield downstream safety electronics from power-line noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43394476671066,"sku":"F7126","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/216._fe6b816c-6803-48ce-9c12-b6403ac3d121.jpg?v=1779245069","url":"https:\/\/www.spareoil.com\/products\/hima-f-7126-brand-new-ip66-emergency-shutdown-power-card","provider":"SpareOil Automation","version":"1.0","type":"link"}