{"product_id":"hima-f-7133-4-channel-safety-power-distribution-module","title":"HIMA F 7133 4-Channel Safety Power Distribution Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe HIMA F7133 (Factory Part Number: 98 4713302 01) functions as a high-integrity, rack-mounted 4-fold power distribution module engineered for the H51X and H51q safety-related automation systems. This specialized assembly partitions a master 24 VDC supply into four independent, monitored output channels to deliver isolated electrical power directly to downstream safety I\/O cards. Optimized for integration inside the F-BASE RACK 11 expansion chassis, the F7133 implements true fail-safe de-energization characteristics, forcing an absolute zero-energy footprint during electrical faults to maintain maximum system safety in petrochemical plants, oil rigs, and power generating stations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF7133\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlternate Part ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e98 4713302 01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-Fold Power Distribution \/ Monitoring Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA H51X and H51q Safety Control Subsystems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget Chassis Frame\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF-BASE RACK 11 Extension Enclosures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 completely independent regulated distribution paths\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Overcurrent Shield\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5x20 mm miniature 4 Amp slow-blow fuses (4 A-T, H)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Switching Delay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 100 ms mechanical response profile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Contact Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 VDC at 4 Amps continuous electrical load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTripped Fuse Residual Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 Volts absolute dead state\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTripped Fuse Residual Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 mA absolute isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMissing Supply Residual Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum 3 Volts leakage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMissing Supply Residual Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 1 mA leakage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Power Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC input at 60 mA nominal consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Rack Footprint\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOccupies 4 TE space allocation slots\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e163 mm x 35 mm x 90 mm (W x H x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Mass\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg (0.55 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +60 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSourcing Supply Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFactory Warranty Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Months from purchase date\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eFail-Safe Zero-Energy Extraction Eliminates Dangerous Residual Current\u003c\/h3\u003e\n\u003cp\u003eStandard industrial power distribution boards often exhibit minor voltage leakage even after a fuse clears, risking continuous excitation of sensitive low-voltage instruments. The HIMA F7133 solves this critical risk by driving the output profile down to an absolute 0 V and 0 mA the instant an onboard fuse blows. This true isolation completely starves the connected loop of electrical energy, ensuring that emergency shutdown (ESD) systems, fuel isolation solenoids, and safety valves drop into their intended de-energized safe positions without delay.\u003c\/p\u003e\n\u003ch3\u003eIndependent Micro-Fuse Clustering Prevents Total Rack Blackouts\u003c\/h3\u003e\n\u003cp\u003eBy splitting incoming master cabinet bus power across four completely isolated output paths, each guarded by its own 4A slow-blow miniature fuse, the F7133 localizes short circuits. If a field instrument suffers a catastrophic housing breach or severe terminal flooding, only the fuse assigned to that specific loop blows. The remaining three output lines continue running uninterrupted, preventing a localized field wire short from collapsing power to the entire I\/O rack or forcing an unnecessary complete plant trip.\u003c\/p\u003e\n\u003ch3\u003eReal-Time Front-Panel Visual Analytics Speed Up Maintenance Diagnosis\u003c\/h3\u003e\n\u003cp\u003eThe F7133 features front-panel diagnostic LED status windows linked directly to internal logic monitoring circuits. These indicators immediately distinguish between a healthy run state, a cleared overcurrent fuse, or a missing master power feed. Plant technicians can scan the cabinet faceplate to identify the faulty channel instantly without opening active terminal covers or deploying external multimeters, reducing troubleshooting time in high-stress operational windows.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat exact replacement fuse specifications does the HIMA F7133 require?\u003c\/p\u003e\n\u003cp\u003eEach of the four channels requires a standard 5x20 mm miniature, 4 Amp slow-blow fuse rated for high breaking capacity (designated as 4 A-T, H). Instrument teams must never replace these with fast-acting fuses, as standard inductive inrush currents from field solenoids will cause nuisance fuse failures during initial channel startup cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the 100 ms relay switching speed affect inductive field loads?\u003c\/p\u003e\n\u003cp\u003eThe built-in switching relays handle the heavy arcing associated with direct current inductive field elements. The 100 ms switching time provides smooth contact transfer while damping transient reverse electromotive force (EMF) voltage surges, preserving the internal structural traces of the card and preventing noise from cross-coupling into adjacent backplane communications lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module be installed into non-HIMA standard industrial DIN rail cabinets?\u003c\/p\u003e\n\u003cp\u003eNo. The mechanical design of the F7133 fits the 4 TE wide Eurocard specification for direct installation into HIMA proprietary chassis frameworks, specifically the F-BASE RACK 11 system. It links via backplane connectors rather than standard rail clamps, allowing it to hook directly into the master power monitoring backbone of the H51X or H51q system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43399394787418,"sku":"F7133","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/241._d2af02d2-c20e-4e1e-9746-78076b9ef3a9.jpg?v=1779325641","url":"https:\/\/www.spareoil.com\/products\/hima-f-7133-4-channel-safety-power-distribution-module","provider":"SpareOil Automation","version":"1.0","type":"link"}