{"product_id":"hima-f-8627-984862765-100base-t-network-processor","title":"HIMA F 8627 984862765 100Base-T Network Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe HIMA F8627 (Factory Part Number: 984862765) functions as a high-integrity Ethernet communication and processing interface engineered for HIMA safety-instrumented systems. This multi-role network processor links safety controllers directly to decentralized plant topologies, distributed control systems (DCS), and supervisory SCADA platforms. Operating over standard 100Base-T physical layers via a rugged RJ45 connection port, the F8627 runs specialized communication protocols like safeethernet and OPC DA. Plant operators utilize this module to pass safety-critical interlock states, diagnostics, and high-speed process data back and forth without compromising the air-gapped isolation of the primary safety loop.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF8627\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e984862765\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet Communication \/ Safety Network Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA HIMax, F60, and HIMatrix Safety Frameworks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Safety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCertified to IEC 61508 \/ IEC 61511 SIL 3 standards\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Transmission Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 100 Mbps fast Ethernet throughput\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Interface Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne (1) 100 Base-T Ethernet port with RJ45 connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Protocols Supported\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003esafeethernet, OPC DA via native HIMA OPC server matrix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMain System Power Source\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC nominal operating input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRanges from 200 mA to 350 mA based on configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGalvanic Isolation Barrier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 V channel-to-backplane and channel-to-channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Chassis Allocation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 19-inch rack mount; 3 Height Units x 4 Width Units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Dimensional Footprint\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 Height Units (3 x 44.45 mm), 4 Width Units (4 x 5.08 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Component Mass\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg (1.76 lbs) raw module state\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Packed Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (4.41 lbs) including protective transit packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +60 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 degrees Celsius dry ambient\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcurement Supply Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eSafeethernet Protocol Protocol Enforces Secure Peer-to-Peer Safety Loops\u003c\/h3\u003e\n\u003cp\u003eThe F8627 executes HIMA's proprietary safeethernet protocol over standard Ethernet networks to connect multiple distributed safety racks safely. This protocol adds safety layers—including sequence numbers, time stamps, and unique signature identifiers—directly onto each data packet. By managing data integrity at the software layer, the F8627 transmits critical safety signals across existing plant-wide fiber or copper backbones, linking emergency shutdown (ESD) nodes together without sacrificing SIL 3 compliance or requiring separate, single-purpose safety wiring runs.\u003c\/p\u003e\n\u003ch3\u003eMassive 500V Isolation Barrier Repels High-Voltage Ground Transients\u003c\/h3\u003e\n\u003cp\u003eIndustrial ethernet runs often stretch between separate control rooms or isolated substation structures that exhibit different electrical ground potentials. The F8627 incorporates a robust galvanic isolation matrix rated up to 500 V between the network interface channels and the core internal backplane bus logic. This physical barrier intercepts stray ground loop currents, electromagnetic field surges, and static discharge bursts at the RJ45 port boundary, shielding the central processor from communication timeouts or fatal chip destruction.\u003c\/p\u003e\n\u003ch3\u003eNative OPC DA Server Integration Streamlines Plant SCADA Mapping\u003c\/h3\u003e\n\u003cp\u003eExporting complex safety registers out to standard factory HMI displays typically requires cumbersome external protocol convertors or specialized, memory-heavy translation software blocks. The F8627 integrates with the native HIMA OPC server suite to stream real-time module status values, diagnostic bits, and live variable data directly over its 100 Mbps pipe. This native architecture translates safety data into open-standard OPC format directly inside the module, lowering central CPU memory load and providing instant data visibility to maintenance teams.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the 500V isolation barrier on the network interface?\u003c\/p\u003e\n\u003cp\u003eThe 500V galvanic isolation barrier prevents high-voltage common-mode surges, induced electrical noise, and ground potential differences between separate plant buildings from entering the central safety backplane. By trapping these electrical transients at the RJ45 interface, the module preserves system integrity and prevents network-borne noise from corrupting active safety loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the F8627 ensure network security while streaming open OPC DA data?\u003c\/p\u003e\n\u003cp\u003eThe F8627 segregates internal processing pipelines at the hardware level. The card executes critical safety interlocks via the safeethernet protocol inside a protected, deterministic routine that remains unpolluted by external traffic. Open communication streams like OPC DA or standard TCP traffic utilize separate memory buffers, allowing the module to pass diagnostic information out to generic SCADA nodes without allowing external network requests to modify or stall active safety functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan technicians swap this communication module while the safety system remains powered?\u003c\/p\u003e\n\u003cp\u003eYes. If the underlying controller platform uses a redundant network configuration, the F8627 supports hot-swapping. You can pull a faulty communication module out of its rack slot and push a brand-new component into place without dropping power to the chassis or disrupting the parallel data paths handled by the companion interface module. Always check that the redundant network link is fully active before removing the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43399433093210,"sku":"F8627","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/245._ea03f79a-68de-44af-9b2a-77f52b19a4de.jpg?v=1779326549","url":"https:\/\/www.spareoil.com\/products\/hima-f-8627-984862765-100base-t-network-processor","provider":"SpareOil Automation","version":"1.0","type":"link"}