{"product_id":"honeywell-10300-1-1-converter-module","title":"Honeywell 10300\/1\/1 FSC Diagnostic and Battery Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell 10300\/1\/1 is a high-reliability DC\/DC Converter Module designed specifically for Fail Safe Control (FSC) systems. This module serves as a critical power component, converting a standard 24 Vdc plant supply voltage into a regulated 5 Vdc output to power internal system modules. It provides essential galvanic isolation between the input and output voltages, ensuring system integrity and noise immunity in safety-critical environments. This unit is a pin-compatible, upgraded replacement for the legacy GK60 module.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual Voltage Conversion: Efficiently converts 24 Vdc to 5 Vdc.\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: Separates supply voltages for enhanced safety and reduced EMI.\u003c\/li\u003e\n\u003cli\u003eHot-Swappable: Designed for maintenance in active systems with strict safety protocols.\u003c\/li\u003e\n\u003cli\u003eInrush Current Limiting: Integrated NTC resistor technology to manage startup current.\u003c\/li\u003e\n\u003cli\u003eOvervoltage Protection: Ensures stable 5 Vdc output to protect downstream components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSafety and Emergency Shutdown (ESD) systems.\u003c\/li\u003e\n\u003cli\u003eBurner and Boiler Management systems.\u003c\/li\u003e\n\u003cli\u003eTurbine and Compressor safeguarding.\u003c\/li\u003e\n\u003cli\u003eProcess Control and DCS power distribution.\u003c\/li\u003e\n\u003cli\u003eFire and Gas detection safety systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e10300\/1\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e136-010875B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 Vdc (with overvoltage protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e12 A (at 0 degC to 45 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 3.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpace Requirements\u003c\/td\u003e\n\u003ctd\u003e8 TE, 3 HE (8 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCool-Down Period:\u003c\/strong\u003e Always keep the module offline for at least 30 seconds after removal or power-off. Failure to do so may prevent the NTC inrush limiter from cooling, leading to a supply voltage dip that could trip the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlacement:\u003c\/strong\u003e Install the module as close as possible to the system bus (e.g., 12-SBUS). Due to tight 5 Vdc tolerance requirements, minimizing cable length is critical to reduce voltage drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use properly sized cabling to ensure stable power delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Configurations:\u003c\/strong\u003e Note that in redundant setups with single I\/O, the output LED may remain illuminated even if the specific module is powered off, as it may be back-fed by the redundant partner unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePin Configuration:\u003c\/strong\u003e For modules without a suffix code or with suffix code 04601, pin d14 (ON\/OFF input) must remain disconnected.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the 10300\/1\/1?\u003c\/h3\u003e\u003cp\u003eThe Honeywell 10300\/1\/1 is a 24 Vdc to 5 Vdc DC\/DC converter module used in Fail Safe Control (FSC) systems to provide regulated power to internal modules.\u003c\/p\u003e\u003ch3\u003eWhy is the 30-second wait time important?\u003c\/h3\u003e\u003cp\u003eThe module uses an NTC resistor to limit inrush current. If the module is re-powered before the NTC has cooled down, the resulting current spike can cause a voltage dip, potentially triggering a system trip.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with older systems?\u003c\/h3\u003e\u003cp\u003eYes, the 10300\/1\/1 is a pin-compatible, upgraded version of the older GK60 module.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43879545339994,"sku":"10300\/1\/1","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_a96ae6b7-670f-4a14-8b75-b79979934949.jpg?v=1787242719","url":"https:\/\/www.spareoil.com\/products\/honeywell-10300-1-1-converter-module","provider":"SpareOil Automation","version":"1.0","type":"link"}