{"product_id":"honeywell-51306920-176-fc-tuio11-universal-analog-i-o","title":"Honeywell 51306920-176 FC-TUIO11 Universal Analog I\/O","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-TUIO11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number: 51306920-176) serves as the most versatile interface within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager SC (S300 IOTA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystem. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Safety I\/O Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexecutes high-precision signal processing for both analog inputs and outputs on a single hardware platform. By supporting configurable 4–20 mA and 0–10 V signals, it streamlines the integration of pressure transmitters, flow meters, and control valve actuators into safety-instrumented functions. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, featuring the latest Rev D engineering improvements for mission-critical SIL3 applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-TUIO11 (51306920-176)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable Analog I\/O (Typically 8 Channels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Input Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–20 mA, 4–20 mA, or 0–10 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Output Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL3 (IEC 61508 Compliant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% of span (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-Channel \u0026amp; Channel-to-System Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS300 IOTA Termination Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg (Net) \/ 0.5 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.2 cm x 12.7 cm x 12.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Configuration Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-TUIO11 eliminates the need for stocking multiple dedicated input and output cards. Engineers configure each channel via software to act as either an input or an output, significantly reducing spare parts inventory and simplifying site-wide standardization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL3-Rated Safety Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery channel undergoes rigorous self-diagnostics to meet SIL3 standards. The module detects internal component drift and external loop faults instantly, ensuring that safety-critical actuators—such as Emergency Shutdown Valves (ESV)—receive accurate commands during hazardous process excursions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust optical and electrical isolation barriers protect the system backplane from field-side transients. This architecture prevents a short circuit in one field transmitter from cascading through the rest of the Safety Manager SC rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Climate Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered with industrial-grade components, the FC-TUIO11 operates in temperatures ranging from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–40°C to +85°C\u003c\/strong\u003e. This capability allows for direct installation in remote instrument enclosures (RIE) without the need for supplemental air conditioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Maintainability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports full hot-swap functionality. Maintenance personnel can replace a module without de-energizing the IOTA or interrupting the logic execution of adjacent safety loops, maintaining 24\/7 operational continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"Universal\" feature benefit my installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnlike fixed-function cards, the FC-TUIO11 allows you to mix sensors (Inputs) and actuators (Outputs) on the same module. This flexibility is ideal for small remote stations where you need a limited number of both signals but only have one available slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific revision of the Safety Manager SC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC-TUIO11 Rev D requires compatible Safety Manager SC firmware. Always verify your current software revision in the Safety Manager Builder to ensure full access to the module's diagnostic and configuration features.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 51306920-176 part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is the unique Honeywell identifier for the FC-TUIO11 assembly. It ensures you are receiving the correct hardware specified for the S300 IOTA subsystem, complete with the appropriate safety certifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We only supply\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell modules. Each unit arrives in its original factory packaging with a clear Rev D designation, ensuring the latest manufacturing standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43187880558682,"sku":"FC-TUIO11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/407_366e6835-4029-4804-a538-bf157abf9d75.jpg?v=1775550289","url":"https:\/\/www.spareoil.com\/products\/honeywell-51306920-176-fc-tuio11-universal-analog-i-o","provider":"SpareOil Automation","version":"1.0","type":"link"}