{"product_id":"honeywell-8c-pcnt02-51454363-275-c300-controller-module","title":"Honeywell 8C-PCNT02 51454363-275 C300 Controller Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell 8C-PCNT02 (51454363-275) is a high-performance C300 Controller module designed for the Experion PKS Series 8 platform. As the central processing unit of the Distributed Control System (DCS), it executes sophisticated regulatory control, high-speed logic, and advanced batch automation strategies. This module is engineered for high-availability environments, including oil and gas refineries, thermal power plants, and large-scale mining operations. By utilizing a deterministic execution environment and supporting robust hardware redundancy, the 8C-PCNT02 minimizes unplanned downtime and optimizes process throughput. Its integration with Series 8 I\/O hardware ensures seamless data exchange and high-density control capabilities in a compact vertical form factor.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Mechanism:\u003c\/strong\u003e Supports 1-to-1 hardware redundancy with automatic state synchronization, ensuring bumpless switchover during primary processor failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Integration:\u003c\/strong\u003e Connects via redundant Fault Tolerant Ethernet (FTE) for secure, reliable communication between controllers, HMIs, and plant assets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Execution:\u003c\/strong\u003e Provides computational power for complex function blocks, including PID control, device control, and custom algorithmic logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e Optimized vertical design for Series 8 cabinets, enhancing passive thermal management via natural convection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe 8C-PCNT02 is intended for use in mission-critical process control applications where high availability and deterministic performance are required. Typical deployments include continuous process control, batch processing, and complex logic execution within the Experion PKS ecosystem.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT02 (51454363-275)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eC300 Control Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e11.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRedundant FTE (Fault Tolerant Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Rate\u003c\/td\u003e\n\u003ctd\u003eSelectable down to 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the controller is mounted in a Series 8 I\/O carrier or compatible rack assembly.\u003c\/li\u003e\n\u003cli\u003eVerify that the power supply is disconnected before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the module to facilitate natural convection cooling.\u003c\/li\u003e\n\u003cli\u003eUse shielded Ethernet cabling for FTE connections to minimize EMI interference in industrial environments.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the cabinet backplane to maintain signal integrity and safety.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to sensitive internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 8C-PCNT02?\u003c\/h3\u003e\u003cp\u003eThe 8C-PCNT02 is a C300 Controller that acts as the central processing unit for the Honeywell Experion PKS Series 8 system, handling regulatory control, logic, and batch automation.\u003c\/p\u003e\u003ch3\u003eDoes this module support redundancy?\u003c\/h3\u003e\u003cp\u003eYes, the 8C-PCNT02 supports 1-to-1 hardware redundancy with automatic state synchronization to ensure bumpless switchover if the primary controller fails.\u003c\/p\u003e\u003ch3\u003eWhat communication protocol does it use?\u003c\/h3\u003e\u003cp\u003eIt utilizes Honeywell's proprietary Fault Tolerant Ethernet (FTE) for redundant, high-reliability network communication.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43893027078234,"sku":"8C-PCNT02 51454363-275","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_d6b08f17-2682-4a7a-aa93-2b114fa15874.jpg?v=1787426604","url":"https:\/\/www.spareoil.com\/products\/honeywell-8c-pcnt02-51454363-275-c300-controller-module","provider":"SpareOil Automation","version":"1.0","type":"link"}