{"product_id":"honeywell-8c-tp0xa1-c300-redundant-profibus-gateway","title":"Honeywell 8C-TP0XA1 C300 Redundant PROFIBUS Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TP0XA1 (51307153-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance PROFIBUS-DP Gateway within the Experion PKS C300 architecture. It establishes a critical communication bridge between C300 controllers and decentralized field devices, including actuators, motor starters, and remote I\/O. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, sealed in factory packaging to ensure peak network integrity in mission-critical process environments such as oil refineries and power generation plants.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DP (RS-485)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Transfer Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 12 Mbps (Auto-sensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9-pin D-sub (Optically Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTE A\/B CAT5e connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports fully redundant system architectures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e430 mA @ 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 mm x 124 mm x 126 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL, CE, RoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Latency Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8C-TP0XA1 processes signal conversion with minimal latency, ensuring real-time response between PROFIBUS field devices and the C300 control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant System Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports dual-fault-tolerant (FTE) connections and redundant gateway pairing. This configuration prevents process trips by maintaining communication even if a single hardware path fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified DIN-Rail Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact 22mm width allows for high-density installation in standard I\/O cabinets. This design solves the problem of limited rack space in brownfield control room upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware-Level Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptical isolation on the 9-pin D-sub interface protects the C300 backplane from external voltage surges or electrical noise originating in the field cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstant Visual Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated LED arrays provide real-time status for power, communication health, and fault conditions, allowing technicians to identify network issues without connecting a laptop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 8C-TP0XA1 handle varying transmission speeds?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supports transmission rates up to 12 Mbps and automatically synchronizes with the speed of the PROFIBUS DP segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support redundant C300 configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. The 8C-TP0XA1 is specifically designed for use in redundant gateway pairs to ensure high availability for critical loops in the Experion PKS environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 8C-TP0XA1 and 8C-TAOXA1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile both belong to the Series 8 family, the 8C-TP0XA1 is a PROFIBUS Gateway module for network communication, whereas the 8C-TAOXA1 typically refers to the Analog Output Termination Assembly. Always verify your system's bill of materials before replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require external power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module receives its 24 VDC power directly via the I\/O chassis backplane, simplifying field wiring and reducing potential points of failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43321095323738,"sku":"8C-TP0XA1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/526..jpg?v=1778049720","url":"https:\/\/www.spareoil.com\/products\/honeywell-8c-tp0xa1-c300-redundant-profibus-gateway","provider":"SpareOil Automation","version":"1.0","type":"link"}