{"product_id":"honeywell-automation-tc-ioli01-51403427-125-16-port-llai","title":"Honeywell Automation TC-IOLI01 51403427-125 16-Port LLAI","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-IOLI01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an authoritative Low-Level Analog Input (LLAI) module engineered for the Honeywell Experion PKS and legacy TDC 3000 Distributed Control Systems (DCS). This module serves as a mechanical necessity for high-density data acquisition, providing 16 independent channels to interface with field sensors and transmitters. By converting low-level voltage and current signals into high-precision digital values, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-IOLI01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures accurate process monitoring for critical variables. Its rugged construction and galvanic isolation make it a trustworthy component for demanding environments such as chemical refineries, power plants, and pharmaceutical manufacturing facilities.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTC-IOLI01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e51403427-125\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-Level Analog Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–5 V, 1–5 V, 4–20 mA (Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Conversion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit Resolution or higher\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTypical Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% of Full Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-System Galvanic Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed sampling for real-time control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS \/ TDC 3000 Chassis Backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg (Net) \/ 0.5 kg (Shipping)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA Industrial Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Engineering Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Integration\u003c\/strong\u003e: Locate an available slot in the Series-A or compatible I\/O chassis. Align the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-IOLI01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the guide rails and press firmly to ensure the backplane connectors are fully engaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e: Use shielded twisted pair (STP) cabling for all 16 input channels. This is an authoritative requirement to minimize electromagnetic interference (EMI) when handling low-level signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Management\u003c\/strong\u003e: For mission-critical process loops, deploy the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-IOLI01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein redundant pairs within the Experion environment. This ensures continuous data flow in the event of a single module failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Calibration\u003c\/strong\u003e: Utilize the Experion Control Builder software to define the specific engineering units and range for each of the 16 channels. Regular software-based zero and span verification is recommended to maintain system expertise and accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the TC-IOLI01 handle noise in industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-IOLI01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eemploys galvanic isolation between the field-side channels and the system-side electronics. This mechanical necessity prevents ground loops and protects the controller from voltage spikes, ensuring a trustworthy signal even in electrically noisy plant sections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with both modern and legacy Honeywell systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51403427-125\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed as a bridge component, offering seamless integration with newer Experion PKS architectures while maintaining full compatibility with legacy TDC 3000 hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between this and high-level input modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-IOLI01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically optimized for low-level signals (like 1-5V or 0-5V). It provides higher sensitivity and specialized A\/D conversion to ensure that small fluctuations in process variables are captured with precise resolution.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43070099554394,"sku":"TC-IOLI01 51403427-125","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/316..jpg?v=1773968546","url":"https:\/\/www.spareoil.com\/products\/honeywell-automation-tc-ioli01-51403427-125-16-port-llai","provider":"SpareOil Automation","version":"1.0","type":"link"}