{"product_id":"honeywell-fc-gmla16-16-channel-analog-input-module","title":"Honeywell FC-GMLA16 | 16-Channel Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-GMLA16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(CC-version) functions as a high-density, 16-channel Analog Input (AI) Field Termination Assembly (FTA) specifically designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager SC (S300 IOTA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This module interfaces critical analog signals from field transmitters—such as pressure, flow, and temperature sensors—directly into the Safety Manager logic solver. Engineered for mission-critical Safety Instrumented Functions (SIF), it carries a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3 certification\u003c\/strong\u003e, ensuring maximum loop integrity in hazardous process environments. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original in Factory Packing\u003c\/strong\u003e, complete with a 12-month factory warranty.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-GMLA16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Independent Analog Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–20 mA, 4–20 mA, or 0–10 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL3 (IEC 61508 Compliant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-resolution A\/D conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% of span (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel \u0026amp; Channel-to-system bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull Hot-swap Support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (Cabinet Installation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (including packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Signal Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-channel architecture maximizes I\/O density within the S300 IOTA rack. This allows engineers to monitor extensive sensor arrays from a single module, effectively reducing cabinet footprint and total system wiring costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL3 Rated Safety Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery channel undergoes rigorous diagnostic testing to meet IEC 61508 SIL3 requirements. The module detects internal drift and external loop faults instantly, ensuring that critical process data remains accurate during emergency shutdown (ESD) scenarios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust isolation barriers protect the system backplane from field-side transients and electromagnetic interference (EMI). This prevents a localized electrical surge at a single transmitter from cascading through the safety rack and affecting adjacent modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade components allow the module to operate across a broad thermal spectrum from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–40°C to +85°C\u003c\/strong\u003e. This capability permits installation in unheated remote instrument enclosures (RIE) in harsh geographic regions without risking hardware failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault Detection \u0026amp; Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated line monitoring identifies open-circuit and short-circuit conditions in real-time. The module provides immediate feedback to the Safety Manager console, allowing maintenance teams to address field wiring issues before they compromise a safety loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Disruptive Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull hot-swap support allows technicians to replace the module under power. This eliminates the need for process shutdowns during routine hardware maintenance or upgrades, ensuring 24\/7 system availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FC-GMLA16 handle 0-10V voltage signals directly?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The module is software-configurable to accept 0–20 mA, 4–20 mA, or 0–10 V signals, providing flexibility for diverse field device types within the same hardware profile.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"CC\" designation signify for this card?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"CC\" (Conformal Coating) designation indicates that the PCB features a protective coating. This enhances resistance to moisture, dust, and corrosive chemicals common in petrochemical and pharmaceutical environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with existing S300 IOTA bases?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-GMLA16 integrates natively with the S300 IOTA termination assembly. Always verify your current Safety Manager firmware revision to ensure full support for the latest diagnostic features.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the condition of the stock?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe provide only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell parts in original factory packaging. Each unit undergoes factory inspection and includes a 12-month warranty to guarantee performance in safety-critical applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43187958022234,"sku":"FC-GMLA16","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/415._0f440ee8-6e97-4d76-b421-3c5d482cdf55.jpg?v=1775553767","url":"https:\/\/www.spareoil.com\/products\/honeywell-fc-gmla16-16-channel-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}