{"product_id":"honeywell-mu-taih02-high-level-analog-input-processor","title":"Honeywell MU-TAIH02 High Level Analog Input Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eThe Honeywell MU-TAIH02 is a high-performance analog input processor engineered for integration into demanding industrial process control environments. This module provides reliable, high-precision signal acquisition for 16 differential channels, making it suitable for monitoring field transmitters and various instrumentation devices in sectors such as power generation, chemical processing, and refinery operations. By utilizing advanced 16-bit A\/D conversion, the MU-TAIH02 ensures stable measurement and high signal integrity, even when subjected to the significant electrical noise typical of large-scale automation facilities.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 differential analog input channels for versatile field connectivity.\u003c\/li\u003e\n\u003cli\u003eSupports multiple signal types including 0-5V, 1-5V, 0.4-2V, and 4-20mA.\u003c\/li\u003e\n\u003cli\u003eRobust common mode rejection of 70 dB (DC to 60 Hz) to mitigate interference.\u003c\/li\u003e\n\u003cli\u003eIntegrated 250 Ohm resistance for current loop conversion.\u003c\/li\u003e\n\u003cli\u003eFast 250 ms total acquisition cycle for high-speed process monitoring.\u003c\/li\u003e\n\u003cli\u003eInternal protection against differential input voltages up to +\/- 30 V.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe MU-TAIH02 is a critical component for Distributed Control Systems (DCS) and industrial automation architectures. It is frequently deployed in turbine monitoring, heavy industrial process control, and complex instrumentation networks where accurate, noise-immune analog data is essential for maintaining system stability and preventing unplanned downtime.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 Differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e0-5V, 1-5V, 0.4-2V, 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit (14-bit utilized)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Rate\u003c\/td\u003e\n\u003ctd\u003e4 samples per second per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Time\u003c\/td\u003e\n\u003ctd\u003e250 ms (all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMRR\u003c\/td\u003e\n\u003ctd\u003e70 dB (DC to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNMRR\u003c\/td\u003e\n\u003ctd\u003e32 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (23.5 deg C)\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.075 percent full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (0-50 deg C)\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.15 percent full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the chassis.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all analog signal inputs to minimize EMI pickup.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is properly seated and locked into the rack to maintain secure electrical contact.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for the control cabinet to ensure the effectiveness of the module's common mode rejection.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation in the equipment room to maintain operating temperatures within the specified range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat input types does the MU-TAIH02 support?\u003c\/strong\u003e\u003cbr\u003eThe module supports voltage and current inputs, including 2-wire and self-powered transmitters, covering standard ranges like 4-20mA and 1-5V.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this module protected against overvoltage?\u003c\/strong\u003e\u003cbr\u003eYes, the hardware includes internal protection circuitry capable of tolerating differential input voltages up to +\/- 30 V without sustaining damage.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44052534853722,"sku":"MU-TAIH02","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_3eff2c4d-b882-44bc-b314-9b0cdf535b69.jpg?v=1789185249","url":"https:\/\/www.spareoil.com\/products\/honeywell-mu-taih02-high-level-analog-input-processor","provider":"SpareOil Automation","version":"1.0","type":"link"}