{"product_id":"honeywell-tc-ffpcx1-power-supply-module-120-230vac-24vdc","title":"Honeywell TC-FFPCX1 Power Supply Module 120\/230VAC 24VDC","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-FFPCX1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance industrial power supply module specifically engineered for the Honeywell Experion PKS and TDC 3000 ecosystems. This module acts as a mechanical necessity for providing stable, regulated 24VDC power to Fieldbus Processors and associated control hardware. Designed for DIN rail mounting, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-FFPCX1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates efficient integration within control cabinets, ensuring that mission-critical processors in refineries, chemical plants, and power generation facilities receive the authoritative electrical foundation required for continuous operation. Its rugged construction and screw terminal interface ensure a trustworthy connection in high-vibration and harsh industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003e(Note: Technical correction applied—the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-FFPCX1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated 24VDC Power Supply unit, often identified by its G9900PS13B sub-component reference, rather than a standalone Fieldbus Processor CPU module.)\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTC-FFPCX1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eT3C G9900PS13B\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Experion PKS, TDC 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 \/ 230 VAC (Selectable\/Universal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Regulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mm DIN Rail Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C (32 °F to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.56 kg (1.24 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA Industrial Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Secure the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-FFPCX1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eonto a standard 35mm DIN rail. Ensure the module is clipped firmly to prevent lateral movement within the cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAC Input Wiring\u003c\/strong\u003e: Connect the 120V or 230V AC supply to the labeled input screw terminals. It is a mechanical necessity to ensure the input voltage matches the site power to avoid internal component stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Output Connection\u003c\/strong\u003e: Route the 24VDC output to the Fieldbus Processor or I\/O bank. Ensure the polarity is correct (+24V and Common) to maintain the integrity of the downstream electronic modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e: Establish a trustworthy safety ground by connecting the earth terminal to the central cabinet ground bar. Proper grounding is an authoritative requirement for EMI suppression and personnel safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAirflow and Clearance\u003c\/strong\u003e: Maintain adequate spacing above and below the module for natural convection cooling. This ensures the unit operates within its specified temperature range even under a full 1.2A load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Power-Up\u003c\/strong\u003e: Monitor the output status via a multimeter or integrated LED indicators (if equipped) upon energizing the AC circuit. A steady 24VDC output confirms the module is ready to support control system operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the TC-FFPCX1 be used in redundant power configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. For mission-critical loops, two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-FFPCX1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules can be utilized in parallel with a diode redundancy module. This setup ensures that if one supply fails, the 24VDC rail remains authoritative via the secondary unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field devices are typically powered by this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1.2A output is ideal for powering the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-FPCXX2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor similar Fieldbus Processors, as well as providing auxiliary power for local I\/O instrumentation and communication gateways.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle voltage fluctuations on the AC line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTC-FFPCX1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes industrial-grade regulation circuitry that filters input noise and maintains a stable 24VDC output despite standard deviations in the 120\/230VAC supply, providing a trustworthy power source for sensitive DCS logic.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43067861401690,"sku":"TC-FFPCX1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/311.jpg?v=1773911065","url":"https:\/\/www.spareoil.com\/products\/honeywell-tc-ffpcx1-power-supply-module-120-230vac-24vdc","provider":"SpareOil Automation","version":"1.0","type":"link"}