{"product_id":"i-o-chassis-housing-honeywell-fc-iochas-0001s-pks-series-c","title":"I\/O Chassis Housing | Honeywell FC-IOCHAS-0001S PKS Series C","description":"\u003ch2\u003eHoneywell FC-IOCHAS-0001S Series C I\/O Module Housing\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-IOCHAS-0001S\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-IOCHAS-0001S\u003c\/strong\u003e I\/O Chassis Assembly (Non-Redundant), operates as a dedicated hardware component for mechanical housing and backplane signal distribution within Honeywell Experion PKS and C300 platforms. It houses single non-redundant Series C I\/O modules, routing power and communications directly through the embedded backplane trace architecture to connected termination assemblies without external jumper cables.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-IOCHAS-0001S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.66 kg to 0.90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e180 mm x 100 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Backplane (Sourced via I\/O Carrier Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS, C300 Controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubsystem Type\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant I\/O Module Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eCorrosion-resistant industrial composite \/ metal alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Termination\u003c\/td\u003e\n\u003ctd\u003eHigh-density backplane connectors; screw-terminal field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RoHS Industrial Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and HART Signal Routing\u003c\/h3\u003e\n\u003cp\u003eThe internal backplane circuitry incorporates galvanically isolated signal traces to maintain channel-to-channel isolation between adjacent I\/O modules and downstream termination assemblies. This electrical separation suppresses common-mode noise and ground loop currents across analog and digital channels. In addition, the trace impedance is engineered to pass high-frequency digital communications alongside standard analog signals, maintaining full compliance with 4-20 mA HART loop protocol standards without attenuation or signal distortion.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can a redundant I\/O module pair be installed in the FC-IOCHAS-0001S?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal backplane of the FC-IOCHAS-0001S lacks the secondary bus traces and switchover logic lines required for dual-redundant module communication. Redundant configurations require a redundant carrier assembly.\u003c\/p\u003e\n\u003cp\u003eQ: Can an FC-CPCHAS control processor chassis be substituted with an FC-IOCHAS-0001S?\u003c\/p\u003e\n\u003cp\u003eA: No. The physical connector keying, internal power distribution planes, and backplane pin assignments differ between processor bases and I\/O housings, preventing cross-compatibility.\u003c\/p\u003e\n\u003cp\u003eQ: Is module replacement supported while field wiring remains powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Field wiring terminates at the chassis base assembly or associated termination block. Technicians can perform warm-swapping of individual electronic I\/O modules without loosening terminal screws or disturbing field cables.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the chassis onto standard Honeywell Series C mounting channels or DIN rails, ensuring all retention clamps latch to prevent motion under mechanical vibration. Run field signal cables through dedicated wire ducts, keeping high-voltage power lines physically separated to eliminate inductive coupling. Ground the metal chassis frame directly to the cabinet functional earth bar using a low-impedance conductor to guarantee electromagnetic compatibility (EMC).\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43070681022554,"sku":"FC-IOCHAS-0001S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/334_1b4f2d95-afc7-4bcc-a9f3-bf965fe83173.jpg?v=1773975845","url":"https:\/\/www.spareoil.com\/products\/i-o-chassis-housing-honeywell-fc-iochas-0001s-pks-series-c","provider":"SpareOil Automation","version":"1.0","type":"link"}