{"product_id":"ic200alg326-versamax-analog-output-module-ge-fanuc","title":"IC200ALG326 VersaMax Analog Output Module | GE Fanuc","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200ALG326\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200ALG326\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for multi-channel current-sourcing loop generation within VersaMax platforms. The module executes digital-to-analog signal conversion across 8 single-ended output channels, driving 4-20 mA or 0-20 mA current loops to control field positioners, actuators, and signal re-transmission loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG320 \/ IC200ALG326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 lbs (0.20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot VersaMax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 mA max at 5 VDC (backplane bus); 185 mA max at full scale (external load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8 single-ended current-sourcing channels (1 group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (default), 0-20 mA (jumper configured)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e13-bit \/ 15-bit internal processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e15 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Inrush Current\u003c\/td\u003e\n\u003ctd\u003e2 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous, 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Functions\u003c\/td\u003e\n\u003ctd\u003eOnboard diagnostics with 2 status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module executes real-time data frame transfers over the VersaMax 5 VDC system backplane, consuming up to 50 mA from internal logic power while converting CPU commands into physical current signals with a maximum update rate of 15 ms. Communication parameters, output range selection, and default fail-safe hold behaviors are initialized directly via host processor software or terminal jumper settings. Operating channels feature continuous frame-to-ground galvanic isolation rated at 250 VAC continuous and 1500 VAC for 1 minute to prevent ground loop noise from corrupting system bus timing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the output current range switched between 4-20 mA and 0-20 mA?\u003c\/p\u003e\n\u003cp\u003eA: The default output range is 4 to 20 mA. Operating in the 0 to 20 mA range requires setting a physical hardware jumper on the wiring base terminal structure.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC200ALG326 be inserted or removed under power (hot-swapped)?\u003c\/p\u003e\n\u003cp\u003eA: Hot insertion is supported by the hardware base, but must be executed strictly aligned and without angular displacement to prevent momentary disruption of backplane power to adjacent modules.\u003c\/p\u003e\n\u003cp\u003eQ: What power draw does the external supply experience when all 8 outputs drive full scale?\u003c\/p\u003e\n\u003cp\u003eA: The external 18-30 VDC user supply draws up to 100 mA with no load connected, and up to 185 mA when all 8 outputs operate at full-scale current output.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module body directly onto the VersaMax carrier or DIN rail slot, verifying positive mechanical alignment with backplane connectors.\u003c\/li\u003e\n\u003cli\u003eSelect output signal range limits (4-20 mA vs. 0-20 mA) using the appropriate terminal jumper settings prior to field connection.\u003c\/li\u003e\n\u003cli\u003eWire field current loops using shielded twisted-pair cabling to prevent inductive coupling and noise interference.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields directly to system ground or via interposing grounding terminals based on cabinet earth layout guidelines.\u003c\/li\u003e\n\u003cli\u003eVerify external 18 to 30 VDC field supply connections before energizing the system rack.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43796916273242,"sku":"IC200ALG326","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200ALG326.jpg?v=1786091536","url":"https:\/\/www.spareoil.com\/products\/ic200alg326-versamax-analog-output-module-ge-fanuc","provider":"SpareOil Automation","version":"1.0","type":"link"}