{"product_id":"ic200alg620-dc-ge-fanuc-4-channel-analog-rtd-interface","title":"IC200ALG620-DC GE Fanuc 4-Channel Analog RTD Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200ALG620-DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers high-precision temperature monitoring for industrial automation via the VersaMax I\/O platform. This 4-channel module interfaces directly with Resistance Temperature Detectors (RTDs), converting thermal resistance into high-resolution 16-bit digital data. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing the critical accuracy required for HVAC control, food processing, and chemical thermal management.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 RTD Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD (Supports common types like Pt100, Ni120)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC (Approx. 130 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 VAC continuous (Optical isolation to logic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.25% of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 ms per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 mm x 66.8 mm x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Thermal Sensing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit resolution provides superior granularity compared to standard 12-bit modules. This allows control systems to detect minute temperature shifts, improving product consistency in heat-sensitive manufacturing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Noise Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust optical isolation (250 VAC) separates the field-side RTD signals from the sensitive PLC backplane. This prevents ground loops and EMI from corrupting data, even in environments with heavy motor interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Data Refresh:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith an update rate of 1 ms per channel, the IC200ALG620-DC supports high-speed process loops. This responsiveness prevents thermal overshoot in fast-acting heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features dedicated OK and PWR LEDs. These indicators provide instant visual verification of both backplane power status and field-side power health, significantly reducing diagnostic downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManufactured in the USA and carrying the 8538909100 tariff code, this module meets rigorous international quality standards for industrial electronic equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IC200ALG620-DC support 2-wire, 3-wire, or 4-wire RTDs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This module primarily supports 3-wire RTD configurations to compensate for lead wire resistance. For 2-wire setups, you must jump the terminals at the carrier, though this may decrease accuracy over long distances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I mix different RTD types on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the hardware supports various RTD profiles, you must configure the software parameters in your GE Fanuc \/ Emerson programming environment (such as Proficy Machine Edition) to match the sensor type connected to each channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While VersaMax carriers allow for module removal, we recommend powering down the field-side power to prevent transients. Always ensure the \"OK\" LED is off before pulling the module from the carrier to maintain backplane integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I handle shield grounding for the RTD cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Connect the cable shields to the ground terminals on the VersaMax carrier. Ensure the DIN rail itself has a low-impedance connection to the main plant earth ground to maximize the module's built-in noise rejection capabilities.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289740378202,"sku":"IC200ALG620-DC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/15._02e896fd-64b0-4922-9262-074a91490086.jpg?v=1777447309","url":"https:\/\/www.spareoil.com\/products\/ic200alg620-dc-ge-fanuc-4-channel-analog-rtd-interface","provider":"SpareOil Automation","version":"1.0","type":"link"}