{"product_id":"ic200dbi001-devicenet-scanner-compatibility-128-byte-i-o-new","title":"IC200DBI001 DeviceNet Scanner Compatibility 128 Byte I\/O New","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200DBI001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance DeviceNet Slave Network Interface Unit (NIU) for the VersaMax I\/O family. This module enables the integration of VersaMax I\/O modules into a DeviceNet network, allowing a master controller to manage distributed inputs and outputs across the factory floor. It acts as the \"head\" of a remote I\/O station, managing communication for up to 8 local I\/O modules. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring seamless connectivity and industrial-grade reliability for your distributed control architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDevice Role\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSlave (Polling Communication)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128 Bytes Input \/ 128 Bytes Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 8 modules per station\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Rates\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 kbps, 250 kbps, 500 kbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Nodes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 64 Nodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5-Pin Open Style (Standard DeviceNet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePWR, OK, FAULT, MOD, NET, FORCE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, cULus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.69 lbs (0.31 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed I\/O Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200DBI001 allows you to place I\/O points closer to the actual field sensors and actuators. This distributed approach eliminates massive wiring bundles back to a central PLC, significantly reducing installation labor and material costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Data Rate Negotiation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports standard DeviceNet speeds of 125, 250, and 500 kbps. This flexibility ensures compatibility with existing network trunk line lengths and meets varying response time requirements for real-time control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Visual Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSix front-panel LED indicators provide immediate feedback on network and module health. These indicators (MOD, NET, FAULT, etc.) allow technicians to distinguish between local hardware failures and network-wide communication issues without connecting specialized software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Efficiency Data Mapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a capacity for 128 bytes of input and output data, a single IC200DBI001 station accommodates high-density digital and analog module combinations. This makes it an ideal choice for complex OEM machinery requiring diverse signal types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module integrates into standard VersaMax carriers. This modularity allows for the rapid replacement of the NIU without disturbing field wiring on the attached I\/O modules, keeping Mean Time to Repair (MTTR) to an absolute minimum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC200DBI001 function as a DeviceNet Master?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200DBI001 operates strictly as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSlave\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edevice. It requires a DeviceNet Master (Scanner), such as an IC200BEM103 or a third-party controller, to initiate communications and manage the network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many I\/O modules can I attach to a single IC200DBI001?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can install up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 VersaMax I\/O modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon the same station as the IC200DBI001. Ensure your total data count does not exceed the 128-byte input\/output limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require external power for DeviceNet communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module logic is powered via the VersaMax backplane, the DeviceNet network itself requires a separate 24VDC power source on the 5-pin connector (V+ and V-) to power the transceiver circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the MAC ID and Baud Rate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou typically configure the Node Address (MAC ID) and Baud Rate using DIP switches located on the module or through software configuration tools, depending on the hardware revision. Always ensure the Baud Rate matches the rest of the DeviceNet network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43218255839322,"sku":"IC200DBI001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/17._e457632e-afc6-4db9-b20d-8215632720a6.jpg?v=1776222916","url":"https:\/\/www.spareoil.com\/products\/ic200dbi001-devicenet-scanner-compatibility-128-byte-i-o-new","provider":"SpareOil Automation","version":"1.0","type":"link"}