{"product_id":"ic200erm001c-ge-fanuc-emerson-isolated-expansion-receiver","title":"IC200ERM001C GE Fanuc Emerson Isolated Expansion Receiver","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200ERM001C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the critical link in high-scale VersaMax PLC architectures. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eisolated expansion receiver module accepts high-speed signals from a transmitter (such as the IC200ETM001) and distributes them across local expansion racks. By providing electrical isolation, it protects the CPU from ground loops and signal interference across multi-rack setups, ensuring seamless data integrity in demanding manufacturing and utility environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIC200ERM001C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersaMax PLC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 26-Pin Female D-Shell Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.3 V (Min) to 5 V (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully Isolated between expansion racks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOn-board Rotary Switch for Rack ID\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLED for Power and Expansion Bus Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLeftmost slot of expansion rack (DIN Rail)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200ERM001C eliminates electrical noise and voltage differentials between the main CPU rack and remote expansion racks. This isolation prevents hardware damage and data corruption in environments with heavy electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Daisy-Chain Topology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual D-shell ports allow engineers to link multiple racks in a series. The module receives the incoming signal and passes it through to the next receiver, simplifying complex wiring layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Addressing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated rotary switch enables immediate hardware-level rack ID assignment. This eliminates the need for complex software configuration during initial setup or module replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCritical Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-visibility LEDs provide real-time feedback on the expansion bus health and power status, significantly reducing downtime during troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines \u0026amp; Application Tips\u003c\/h3\u003e\n\u003cp\u003eTo ensure optimal performance, always install the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ERM001C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eleftmost slot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof the expansion rack. It must be paired with an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ETM001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransmitter located in the main or previous rack. Ensure all D-shell cables are shielded and securely fastened to the ports to maintain signal continuity across the bus.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the IC200ERM001C without a transmitter module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. This module is a receiver. It requires an IC200ETM001 (or compatible transmitter) to provide the upstream communication signal from the CPU rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a separate external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA: No. The IC200ERM001C draws its operating power directly from the backplane power supply installed on the expansion rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of the rotary switch?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA: The rotary switch sets the unique Rack ID for the expansion rack. This allows the CPU to correctly address and identify the I\/O modules located in that specific rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the \"C\" version compatible with older IC200ERM001 versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eA: Yes, the \"C\" suffix typically denotes a later hardware revision or firmware update, but it maintains backwards compatibility with existing VersaMax expansion systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43289751289946,"sku":"IC200ERM001C","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/529.jpg?v=1777448190","url":"https:\/\/www.spareoil.com\/products\/ic200erm001c-ge-fanuc-emerson-isolated-expansion-receiver","provider":"SpareOil Automation","version":"1.0","type":"link"}