{"product_id":"ic200mdd845-ge-versamax-mixed-i-o-module","title":"IC200MDD845 GE VersaMax Mixed I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200MDD845\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDD845\u003c\/strong\u003e Combination Discrete Input and Output Module, operates as a dedicated hardware component for discrete signal conditioning and load switching within VersaMax I\/O platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDD845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ Fanuc (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.63 lbs (0.28 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax Carrier Module Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial Enclosure Operating Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e270 mA maximum from Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eVersaMax I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Channel Count\u003c\/td\u003e\n\u003ctd\u003e24 Points (16 Discrete Inputs \/ 8 Relay Outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Nominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (18 to 30 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Current\u003c\/td\u003e\n\u003ctd\u003e2.0 to 5.5 mA (On-state), 0 to 0.5 mA (Off-state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contact Type\u003c\/td\u003e\n\u003ctd\u003e8 Form A (Normally Open) Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 125 VDC, 0 to 265 VAC (47 to 63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating (Resistive)\u003c\/td\u003e\n\u003ctd\u003e2.0 A at 5-265 VAC, 2.0 A at 5-30 VDC, 0.2 A at 31-125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel isolation on outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Base Required\u003c\/td\u003e\n\u003ctd\u003eIC200CHS Series Carrier Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDD845 manages high-speed discrete data exchange across the VersaMax carrier backplane, preserving deterministic backplane bus communication velocity during concurrent 24-point update cycles. Onboard memory registers maintain parameter synchronization with the primary VersaMax CPU or network interface unit, validating module firmware flash compatibility to execute real-time discrete input scanning and relay actuation without bus degradation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane current drawing limits for the IC200MDD845?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum current of 270 mA from the backplane 5 VDC supply rail, depending on the total number of concurrently active input and output points.\u003c\/p\u003e\n\u003cp\u003eQ: Are the Form A relay output channels on the IC200MDD845 fused internally?\u003c\/p\u003e\n\u003cp\u003eA: No, the output channels are individually isolated Form A relay contacts but do not include internal fusing or snubber circuits; external circuit protection must be provided.\u003c\/p\u003e\n\u003cp\u003eQ: What carrier base is required to mount the IC200MDD845 in a VersaMax I\/O rack?\u003c\/p\u003e\n\u003cp\u003eA: The module requires an IC200CHS series carrier base to establish backplane connection and facilitate field wiring terminations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect backplane power to the I\/O carrier base and isolate external field voltage sources prior to installing or removing the module.\u003c\/li\u003e\n\u003cli\u003ePut on an ESD grounding wrist strap connected to an unpainted metal surface on the enclosure frame to prevent static damage.\u003c\/li\u003e\n\u003cli\u003eAlign the module card edge connectors with the IC200CHS carrier base guide slots and push firmly until the module latches securely.\u003c\/li\u003e\n\u003cli\u003eEnsure 24 VDC positive logic input wiring and high-voltage output load connections maintain separate conduit pathways to prevent inductive cross-talk.\u003c\/li\u003e\n\u003cli\u003eApply external fusing or surge suppression devices on each isolated Form A relay output channel to protect field contacts against inductive load transients.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43833194446938,"sku":"IC200MDD845","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200MDD842_f6636dc0-9443-45c1-9911-74e803fe2145.png?v=1786523227","url":"https:\/\/www.spareoil.com\/products\/ic200mdd845-ge-versamax-mixed-i-o-module","provider":"SpareOil Automation","version":"1.0","type":"link"}