{"product_id":"ic200mdl240-ge-fanuc-versamax-discrete-input-module","title":"IC200MDL240 GE Fanuc VersaMax Discrete Input Module","description":"\u003cp\u003eConfigured for discrete AC signal processing in VersaMax control systems, the \u003cstrong\u003eGE Fanuc IC200MDL240\u003c\/strong\u003e (\u003cstrong\u003eIC200MDL240\u003c\/strong\u003e Discrete Input Module) provides direct physical\/electrical execution. The unit accepts 16 discrete input channels operating at 120 VAC nominal voltage, converting field binary signals into 16-bit discrete data format across the backplane bus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 lbs (0.17 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm x 66.8 mm x 50.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e110 mA maximum backplane current at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 discrete input points (2 groups of 8 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0-132 VAC (47-63 Hz), 120 VAC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-State Range\u003c\/td\u003e\n\u003ctd\u003e70-132 VAC (7 mA minimum current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Range\u003c\/td\u003e\n\u003ctd\u003e0-40 VAC (1.5 mA maximum current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e8.6 kOhms at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eON: 1 cycle; OFF: 2 ms minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003eNone required (logic powered from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003eGroup-to-group: 250 VAC continuous (1500 VAC for 1 min); Optical\/Frame: 1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Display\u003c\/td\u003e\n\u003ctd\u003e16 individual channel LEDs and 1 backplane status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module executes binary signal evaluation across two groups of 8 channels, interfacing directly with VersaMax CPUs or Network Interface Units (NIUs). Backplane communication velocity relies on a maximum current draw of 110 mA from the 5 VDC bus, eliminating the requirement for external field power to energize internal logic circuits. Optical isolation provides 250 VAC continuous isolation between user inputs, backplane logic, and system frame ground. Firmware flash compatibility within the host controller enables seamless I\/O mapping and diagnostic status reporting via the onboard LED array.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200MDL240 require an external power supply to operate field inputs?\u003c\/p\u003e\n\u003cp\u003eA: No external power supply is required; internal module logic draws all operational power directly from the backplane (110 mA maximum at 5 VDC).\u003c\/p\u003e\n\u003cp\u003eQ: What isolation level is provided between the individual input channels?\u003c\/p\u003e\n\u003cp\u003eA: The module features group-to-group optical isolation rated at 250 VAC continuous (1500 VAC for 1 minute) between its two 8-channel groups.\u003c\/p\u003e\n\u003cp\u003eQ: Does vertical DIN-rail mounting impact module performance?\u003c\/p\u003e\n\u003cp\u003eA: The module supports both horizontal and vertical mounting orientations without performance derating, though input voltage thermal deratings apply at 132 VAC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSnap the carrier base onto a standard 35 mm DIN rail in either a horizontal or vertical orientation.\u003c\/li\u003e\n\u003cli\u003eInsert the IC200MDL240 module firmly into the VersaMax I\/O carrier until the locking mechanisms engage.\u003c\/li\u003e\n\u003cli\u003eWire incoming 120 VAC field inputs to the designated group terminals, maintaining neutral common wiring per 8-channel group.\u003c\/li\u003e\n\u003cli\u003eVerify that signal wiring is separated from high-voltage DC or noisy inductive lines to prevent signal distortion.\u003c\/li\u003e\n\u003cli\u003ePower up the system backplane and confirm that the backplane LED illuminates green to signal proper communication.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43796924235866,"sku":"IC200MDL240","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200MDL2402.png?v=1786092696","url":"https:\/\/www.spareoil.com\/products\/ic200mdl240-ge-fanuc-versamax-discrete-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}