{"product_id":"ic200mdl741-versamax-discrete-output-module-ge","title":"IC200MDL741 VersaMax Discrete Output Module | GE","description":"\u003cp\u003eConfigured for 24 VDC discrete signal switching in VersaMax I\/O systems, the \u003cstrong\u003eGE IC200MDL740\u003c\/strong\u003e (\u003cstrong\u003eIC200MDL741\u003c\/strong\u003e Discrete Output Module) provides direct physical\/electrical execution. The module provides 16 positive logic (sourcing) output channels arranged in a single group, routing current to external field loads from an external 18 to 30 VDC supply. Hardware features include integrated electronic short-circuit protection, overcurrent protection, and free-wheeling diodes for inductive transient suppression, maintaining dynamic control with a maximum ON\/OFF response time of 0.5 ms across all points.\u003c\/p\u003e\n\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL741\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg (0.25 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax Single-Slot Carrier Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e75 mA @ 5 VDC (Backplane current draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule ID\u003c\/td\u003e\n\u003ctd\u003eFFFF8080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Discrete Outputs (1 isolated group of 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSourcing \/ Positive Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point @ 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e0.5 ms maximum (ON and OFF state transitions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eElectronic short-circuit, overcurrent, and internal free-wheeling diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eNone (Group-to-Group or Point-to-Point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e16 Point LEDs (ON\/OFF and Overload), 1 OK LED, 1 FLD PWR LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Integration \u0026amp; Field Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL741 integrates into VersaMax backplanes, drawing 75 mA from the 5 VDC bus to power local supervisory logic while executing high communication velocity. When operating within Profinet or EtherNet\/IP deterministic network drops, the module maintains microsecond-level synchronization between backplane frame updates and output physical state transitions. High-density I\/O scaling is facilitated through tool-free carrier base mounting, where native Module ID flags enforce firmware flash compatibility and hot-swap validation during live unit substitution.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are external free-wheeling diodes required when driving inductive loads with the IC200MDL741?\u003c\/p\u003e\n\u003cp\u003eA: No. The IC200MDL741 features integrated internal free-wheeling diodes across each channel, suppressing inductive voltage spikes without external snubber networks.\u003c\/p\u003e\n\n\u003cp\u003eQ: How are external DC field power sources terminated on the module carrier?\u003c\/p\u003e\n\u003cp\u003eA: External field power supply lines must be connected to the module carrier terminal points A17 (DC+) and A18 (DC-) to provide field output driving power.\u003c\/p\u003e\n\n\u003cp\u003eQ: Can the IC200MDL741 be hot-swapped during active controller operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports live insertion and removal on VersaMax carrier bases without removing field wiring, provided physical alignment is maintained to safeguard backplane connector pins.\u003c\/p\u003e\n\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Isolation\u003c\/strong\u003e: Disconnect primary cabinet power and field load supplies prior to mounting, removing, or wiring the carrier base.\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCarrier Base Insertion\u003c\/strong\u003e: Align the IC200MDL741 module with the guide rails of the VersaMax I\/O carrier. Press down until side latching tabs fully engage with the carrier frame.\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Power Wiring\u003c\/strong\u003e: Wire external 18 to 30 VDC power to terminals A17 (DC+) and A18 (DC-) on the carrier base. Ensure proper wire sizing for maximum total output current loading.\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Grounding\u003c\/strong\u003e: Mount the carrier assembly on an electrically grounded metal DIN rail to optimize EMC protection and mitigate high-frequency electrical noise.\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Separation\u003c\/strong\u003e: Route low-voltage DC discrete output conductors in separate cable raceways from AC power distribution lines and variable frequency drive cables.\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43791598125146,"sku":"IC200MDL741","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200MDL730_c06840bc-c1a7-497d-bae6-fdbd826b7f5a.png?v=1785983362","url":"https:\/\/www.spareoil.com\/products\/ic200mdl741-versamax-discrete-output-module-ge","provider":"SpareOil Automation","version":"1.0","type":"link"}