{"product_id":"ic200mdl930-ge-fanuc-versamax-relay-output-module","title":"IC200MDL930 GE Fanuc VersaMax Relay Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDL930\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDL930\u003c\/strong\u003e Relay Output Module, operates as a dedicated hardware component for isolated discrete switching within VersaMax I\/O platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Various\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg (0.56 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 30 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e243 mA (up to 435 mA maximum current draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 individually isolated points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Form\u003c\/td\u003e\n\u003ctd\u003eForm A (Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003eSilver alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Architecture\u003c\/td\u003e\n\u003ctd\u003eFixed coil, moving armature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 125 VDC; 0 to 265 VAC (47 to 63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Current Rating\u003c\/td\u003e\n\u003ctd\u003e2.0 A (5 to 265 VAC \/ 5 to 30 VDC); 0.2 A (31 to 125 VDC); 10 mA minimum per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum (On\/Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Frequency\u003c\/td\u003e\n\u003ctd\u003e20 cycles per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute (channel-to-channel and channel-to-logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Diagnostics\u003c\/td\u003e\n\u003ctd\u003eModule OK LED, 8 individual output channel LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL930 incorporates 8 individually isolated Form A relay contacts, delivering high channel-to-channel isolation while supporting flexible I\/O density scaling across VersaMax backplane base units. Interfacing directly with the local CPU carrier, the module maintains deterministic backplane bus communication velocity during output image updates. Onboard firmware flash compatibility ensures synchronized relay state transitions across distributed racks, preventing backplane communication timeouts when managing inductive field actuators.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200MDL930 contain internal protective fuses or snubber circuits for the relay contacts?\u003c\/p\u003e\n\u003cp\u003eA: No, the module does not include internal output fuses or snubber circuits. External protection circuits, such as fast-acting inline fuses or inductive suppression networks, are recommended for field wiring connected to reactive loads.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane current draw requirements for the IC200MDL930?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a nominal 243 mA from the 5 VDC backplane bus, with a maximum total backplane current consumption of 435 mA when all eight relay coils are fully energized.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Carrier Engagement\u003c\/strong\u003e: Align the module with the carrier base sub-assembly and push firmly until the locking tabs snap into place. Ensure power is removed from the carrier backplane prior to installation or removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring and Contact Isolation\u003c\/strong\u003e: Wire field loads to the designated carrier terminals. Because each relay channel is individually isolated, distinct external AC or DC power sources may be connected to individual channels within the specified 0-265 VAC \/ 0-125 VDC voltage limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Noise Suppression\u003c\/strong\u003e: Install RC snubbers or freewheeling diodes directly across inductive field loads to prevent arc discharge across the silver alloy contacts and maintain systemic noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43833423790170,"sku":"IC200MDL930","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200MDL930.png?v=1786527546","url":"https:\/\/www.spareoil.com\/products\/ic200mdl930-ge-fanuc-versamax-relay-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}