{"product_id":"ic200pwr002-ge-fanuc-versamax-24vdc-power-supply-new","title":"IC200PWR002 GE Fanuc VersaMax 24VDC Power Supply New","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200PWR002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a vital supplemental power source for the GE VersaMax PLC and I\/O system. It converts a nominal 24VDC input into regulated 5VDC and 3.3VDC power to drive the backplane bus. This module proves essential when the total current draw of the CPUs, Network Interface Units (NIUs), and I\/O modules exceeds the capacity of the primary power supply. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring stable voltage regulation and electrical protection for your high-density automation racks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Fanuc (Emerson Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal (Range: 18–30 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC and 3.3 VDC Regulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 Amperes (Maximum combined)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3.3VDC Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 A Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5VDC Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 A (minus 3.3V current used)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHoldup Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20A @ 24VDC \/ 25A @ 30VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShort Circuit, Overload, and Reverse Polarity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Rack Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IC200PWR002 allows you to expand your VersaMax station beyond the limits of a single power supply. By injecting additional current into the backplane, it supports high-density analog modules and communication interfaces that demand higher power consumption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Voltage Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module simultaneously regulates both 5VDC and 3.3VDC lines. This dual-output capability ensures that newer, low-voltage internal circuitry and standard logic components receive stable, ripple-free power within a single module footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Electrical Safeguards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated circuitry actively protects the system against short circuits, overloads, and reverse polarity wiring errors. These safeguards prevent localized faults from damaging expensive CPU or I\/O hardware across the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Booster Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installed on a Booster Carrier, the IC200PWR002 works in tandem with the primary power supply to distribute load effectively. This configuration maintains system uptime even when the I\/O count increases during facility upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Thermal Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes a low-heat dissipation design, requiring only 11W of input power. Its compact size fits easily into standard VersaMax carriers, maximizing DIN rail space in cramped control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhen do I need to add an IC200PWR002 to my VersaMax system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must add this supplemental power supply if your total module current calculation exceeds the 5VDC or 3.3VDC rating of your main Power Supply or NIU. High-density analog or specialized communication modules often necessitate the use of an IC200PWR002.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC200PWR002 be used as the primary power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTypically, this module acts as a supplemental supply used on a Booster Carrier. It complements the main supply to provide additional current to modules further down the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide isolation between the 24VDC input and the backplane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC200PWR002 is a non-isolated power supply. If your application requires high-voltage isolation between the field power and the PLC logic, ensure your primary power supply or external 24VDC source provides the necessary galvanic isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if I exceed the 1.5A total current limit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated overload protection will trigger, dropping the output voltage to protect the internal components. You should recalculate your power requirements and potentially add another supplemental supply if this occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43217832902746,"sku":"IC200PWR00","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/9._1dc75f08-85b8-4770-b588-59929fca64ca.jpg?v=1776219452","url":"https:\/\/www.spareoil.com\/products\/ic200pwr002-ge-fanuc-versamax-24vdc-power-supply-new","provider":"SpareOil Automation","version":"1.0","type":"link"}