{"product_id":"ic200uex212-versamax-discrete-expansion-unit-ge-fanuc","title":"IC200UEX212 VersaMax Discrete Expansion Unit | GE Fanuc","description":"\u003cp\u003eConfigured for discrete field signal processing in VersaMax Micro PLC networks, the \u003cstrong\u003eGE Fanuc IC200UEX212\u003c\/strong\u003e (\u003cstrong\u003eIC200UEX212\u003c\/strong\u003e Discrete Expansion Unit) provides direct physical\/electrical execution for 16 DC inputs and 12 relay outputs.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UEX212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Various\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 mm x 90 mm x 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8 W input power rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e28 Discrete I\/O Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Channels\u003c\/td\u003e\n\u003ctd\u003e16 points at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output Channels\u003c\/td\u003e\n\u003ctd\u003e12 electromechanical relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Auxiliary Power\u003c\/td\u003e\n\u003ctd\u003e200 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Resistive Load Rating\u003c\/td\u003e\n\u003ctd\u003e2 A at 24 VDC \/ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail or direct panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC200UEX212 interfaces directly with the main VersaMax controller base, providing expanded I\/O density scaling within a compact 150 mm footprint. Internal bus transceiver circuits handle high-speed signal updates to maintain determinism and backplane bus communication velocity across all 28 channels. Onboard logic circuits ensure full firmware flash compatibility, allowing synchronized image-table updates and status diagnostics between the expansion unit and the local CPU interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the continuous load current limits for the output relays on the IC200UEX212?\u003c\/p\u003e\n\u003cp\u003eA: The 12 electromechanical relay outputs support a maximum resistive load rating of 2 A per point at either 24 VDC or 240 VAC line levels.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC200UEX212 provide auxiliary power distribution for connected field sensors?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit includes an onboard auxiliary power supply output capable of sourcing up to 200 mA at 24 VDC to energize external sensing devices.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Panel\/DIN Rail Mounting\u003c\/strong\u003e: Secure the module onto a 35 mm DIN rail or mount directly to a metal backpanel using M4 hardware. Maintain at least 50 mm clearance around ventilation slots to ensure unassisted thermal dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField I\/O Terminal Wiring\u003c\/strong\u003e: Terminate 24 VDC input and relay load conductors into the front terminal block assembly. Route inductive AC output wiring in separate wire trunks away from low-voltage DC input lines to prevent cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Grounding\u003c\/strong\u003e: Connect the cabinet chassis protective earth conductor directly to the grounding terminal of the unit to ensure surge suppression and electromagnetic immunity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43833341575258,"sku":"IC200UEX212","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200UEX2111_6e835bf6-bf46-46c0-91fb-04d35f615f37.png?v=1786525996","url":"https:\/\/www.spareoil.com\/products\/ic200uex212-versamax-discrete-expansion-unit-ge-fanuc","provider":"SpareOil Automation","version":"1.0","type":"link"}