{"product_id":"ic670alg620-ge-fanuc-4-channel-rtd-analog-input-module","title":"IC670ALG620 GE Fanuc | 4-Channel RTD Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG620 (Model: IC670ALG620)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision analog input module designed for Resistance Temperature Detector (RTD) acquisition within the GE Fanuc Field Control I\/O system. This module facilitates the direct interface of four independent RTD sensors to a central controller without the need for external signal transmitters. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG620 (Part Number: IC670ALG620)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to support both 3-wire and 4-wire RTD configurations, providing automatic lead resistance compensation to ensure high accuracy over long cable distances.\u003c\/p\u003e\n\u003cp\u003eEquipped with a 15-bit plus sign resolution, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG620 (Model: IC670ALG620)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edetects minute thermal shifts, making it essential for critical process monitoring in chemical, pharmaceutical, and power generation sectors. The module features integrated intelligence for detecting field faults such as open sensors, short circuits, and out-of-range conditions, transmitting specific diagnostic bits to the Bus Interface Unit (BIU) for rapid troubleshooting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG620\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaintains high signal integrity through rugged galvanic isolation and advanced digital filtering.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Fanuc (Emerson)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG620\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: Field Control I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Analog Input (RTD Specialized)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 4 Independent channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRTD Support\u003c\/strong\u003e: 3-wire and 4-wire (Platinum, Nickel, Copper)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Resolution\u003c\/strong\u003e: 15 bits plus sign\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e: 210 ms (at 60 Hz) \/ 230 ms (at 50 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Fault Detection\u003c\/strong\u003e: Open RTD, Short circuit, Under\/Overrange, High\/Low alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNormal Mode Rejection\u003c\/strong\u003e: 60dB at 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e: 120dB at 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Lead Resistance\u003c\/strong\u003e: 5 ohms per lead (for rated accuracy)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Sensitivity\u003c\/strong\u003e: ±0.004% of reading (0°C to 60°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Current Draw\u003c\/strong\u003e: 190 mA maximum from the BIU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: 1500 VAC (1 minute); 250 VAC (Continuous)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to +60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: –40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: Standard Field Control module footprint\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.45 kg (1.00 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42870841835610,"sku":"IC670ALG620","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/200.jpg?v=1772242457","url":"https:\/\/www.spareoil.com\/products\/ic670alg620-ge-fanuc-4-channel-rtd-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}