{"product_id":"ic693acc301-ge-series-90-70-lithium-backup-battery","title":"IC693ACC301 GE Series 90-70 Lithium Backup Battery","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC693ACC301\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693ACC301\u003c\/strong\u003e Lithium Backup Battery, operates as a dedicated hardware component for volatile memory retention within Series 90-70 PLC platforms. The cell delivers continuous electrical biasing to the internal CMOS RAM layout to maintain runtime configurations and user application code during periods of primary rack power isolation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693ACC301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard sub-module cell weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEnclosed form factor for internal power supply cavity mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 25 deg C (32 to 77 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive cell discharge (nominal chemistry current rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Chemistry\u003c\/td\u003e\n\u003ctd\u003eLithium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003e2-wire lead with Berg female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eInternal plastic clip mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget System Memory\u003c\/td\u003e\n\u003ctd\u003eCMOS RAM within base power supply assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C (-40 to 185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe IC693ACC301 prevents code loss across Series 90-70 hardware structures, mitigating memory state errors that could interrupt backplane bus communication velocity parameters upon system reboot. By maintaining the raw configuration registers during unpowered states, the component assists in direct I\/O density scaling recovery when the primary controller platform initialises. Firmware flash compatibility checks depend on the seamless preservation of system variables, ensuring that step configurations and operational parameters pass cleanly to the processor without data corruption or execution jitter.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC693ACC301 battery be exchanged while the PLC remains energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the cell supports live exchange while primary power is applied to preserve the CMOS RAM data. However, qualified personnel must execute this operation due to exposed high voltages inside the power supply enclosure.\u003c\/p\u003e\n\u003cp\u003eQ: What is the physical connection interface for this backup cell?\u003c\/p\u003e\n\u003cp\u003eA: The battery features a 2-wire lead assembly terminated in a small Berg female connector, which seats directly into the mating pin header on the power supply printed circuit board (PCB).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Safety Compliance:\u003c\/strong\u003e Disconnect or isolate high-voltage power paths prior to opening the cover plate if personnel are not certified for live electrical line operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Securing Protocol:\u003c\/strong\u003e Snap the cell body completely into the integrated internal plastic clip located on the inside of the power supply plate to prevent physical movement or vibration-induced lead separation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Thermal Thresholds:\u003c\/strong\u003e Maintain standby inventory in a controlled location within the -40 to 85 deg C range. Avoid high temperature zones to prevent accelerated passivating layer growth and internal cell degradation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43623583416410,"sku":"IC693ACC301","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693ACC301.png?v=1783587554","url":"https:\/\/www.spareoil.com\/products\/ic693acc301-ge-series-90-70-lithium-backup-battery","provider":"SpareOil Automation","version":"1.0","type":"link"}