{"product_id":"ic694chs392-ge-fanuc-pacsystems-rx3i-10-slot-serial-expansion-baseplate","title":"IC694CHS392 GE Fanuc PACSystems RX3i 10-Slot Serial Expansion Baseplate","description":"\u003cp\u003eConfigured for remote I\/O rack expansion in PACSystems RX3i platforms, the \u003cstrong\u003eGE Fanuc IC694CHS392\u003c\/strong\u003e (\u003cstrong\u003eIC694CHS392\u003c\/strong\u003e Serial Expansion Baseplate) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694CHS392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ As specified on label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.06 lbs (0.94 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RX3i 10-slot baseplate footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA @ 5 VDC (internal backplane logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Slots\u003c\/td\u003e\n\u003ctd\u003e10 I\/O slots + 1 Power Supply slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU Support\u003c\/td\u003e\n\u003ctd\u003eNone (No CPU slot provided)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i Analog, Discrete, and Special-Function Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Interface\u003c\/td\u003e\n\u003ctd\u003e25-pin female D-shell connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Expansion Distance\u003c\/td\u003e\n\u003ctd\u003e50 feet (15 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003ePanel mounting (front mounting \/ recessed mounting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-Swap Support\u003c\/td\u003e\n\u003ctd\u003eHot insertion and removal not supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC694CHS392 expands RX3i control system architecture by routing serial expansion signals from a main CPU rack to 10 additional option and I\/O slots. Communicating across a 25-pin female D-shell interface over cable runs up to 50 feet (15 meters), the baseplate preserves high backplane bus communication velocity across high-density analog, discrete, and specialty I\/O modules. Internal backplane logic operates at a current draw of 150 mA at 5 VDC, maintaining bus arbitration without requiring local CPU overhead.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC694CHS392 expansion baseplate support hot insertion and removal of I\/O modules? A: No, hot insertion and removal of modules is not supported on the IC694CHS392 serial expansion baseplate.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum cable length supported for connecting the IC694CHS392 to the main PLC rack? A: The maximum expansion bus cable distance supported is 50 feet (15 meters) using the 25-pin D-shell expansion interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the baseplate to a grounded metal enclosure backpanel using screws through all mounting locations, ensuring proper physical contact for enclosure grounding.\u003c\/li\u003e\n\u003cli\u003eDe-energize the entire rack power supply before inserting or removing I\/O modules or connecting serial expansion bus cables.\u003c\/li\u003e\n\u003cli\u003eSecure the 25-pin expansion cable to the female D-shell connector using integrated jack-screws to prevent cable loosening from operational vibration.\u003c\/li\u003e\n\u003cli\u003eEnsure total expansion cable routing does not exceed 50 feet (15 meters) and is run separately from high-voltage field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43712314048602,"sku":"IC694CHS392","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693CHS392.png?v=1784774940","url":"https:\/\/www.spareoil.com\/products\/ic694chs392-ge-fanuc-pacsystems-rx3i-10-slot-serial-expansion-baseplate","provider":"SpareOil Automation","version":"1.0","type":"link"}