{"product_id":"ic694mdl646-ge-rx3i-pacsystems-module","title":"IC694MDL646 GE RX3i PACSystems Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC694MDL646\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC694MDL646\u003c\/strong\u003e Input Module utilized to execute discrete input sensing across RX3i PACSystems platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694MDL646\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.63 lbs (0.28 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RX3i rack slot dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA from 5 VDC bus, 125 mA from 24 VDC internal\/external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16 channels (1 groups of 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Positive or Negative logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e7 mA typical per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e11.5 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e3.2 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e1.1 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e1 ms average (On and Off transitions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e16 x Green LEDs (Channel state), 2 x Blue bands (Low-voltage indication)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e15 G for 11 ms duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e10 to 57 Hz at 0.0524 mm peak displacement, 57 to 500 Hz at 1.0 G acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces with the RX3i control backplane, enabling synchronized state updates within the CPU sweep execution framework. High-frequency digital sampling arrays stabilize the 1 ms input response profile while maximizing physical I\/O density scaling inside a single sub-rack assembly. Internal isolation structures safeguard logic processing circuits from the high-speed bus lines, maintaining parallel data block transfers without signal distortion under maximum channel load conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC694MDL646 module support internal power distribution for field sensors?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal circuitry limits current consumption parameters to module logic tracking. Field devices, such as electronic proximity switches, limit switches, and pushbuttons, must be powered directly from an independent external 24 VDC voltage source.\u003c\/p\u003e\n\u003cp\u003eQ: What is the technical meaning behind the two blue bands located on the faceplate assembly?\u003c\/p\u003e\n\u003cp\u003eA: The dual blue band indentation acts as a permanent, high-visibility mechanical color classification denoting a low-voltage DC module footprint. This prevents physical terminal terminal cross-connection with adjacent high-voltage AC module variants during installation loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Retention\u003c\/strong\u003e: Isolate all active power configurations feeding the targeted baseplate before physical installation. Insert the card into the selected slot guide, ensuring full seating alignment into the backplane connector block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Signal Wire Routing\u003c\/strong\u003e: Run low-voltage 24 VDC input control lines separately from high-voltage AC power loops to eliminate parasitic capacitive and inductive signal interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocols\u003c\/strong\u003e: Verify that the RX3i chassis grounding bar is directly bonded to the enclosure backpanel substrate, complying with low-impedance industrial system ground paths to shield discrete switching nodes from electrical transients.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43616539443290,"sku":"IC694MDL646","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694MDL646.png?v=1783482192","url":"https:\/\/www.spareoil.com\/products\/ic694mdl646-ge-rx3i-pacsystems-module","provider":"SpareOil Automation","version":"1.0","type":"link"}