{"product_id":"ic694mdl741-ge-fanuc-pacsystem-rx3i-discrete-output-module","title":"IC694MDL741 GE Fanuc PACSystem RX3i Discrete Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC694MDL741\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC694MDL741\u003c\/strong\u003e Discrete Output Module, operates as a dedicated hardware component for 12\/24 VDC negative logic signal switching within PACSystem RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694MDL741\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg (0.31 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RX3i single-slot module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e110 mA from 5 VDC backplane bus (all outputs ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 (2 groups of 8 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC (+20%, -15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point; 2.0 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e0.5 V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e1.0 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Times\u003c\/td\u003e\n\u003ctd\u003eOn: 2 ms maximum \/ Off: 2 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous (1500 VAC for 1 minute) Field-to-Backplane and Group-to-Group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL741 exchanges discrete channel states directly via the high-speed RX3i backplane bus, enabling deterministic update rates across all 16 output points. Optimized for high-density I\/O configurations, the module distributes current consumption over two distinct 8-channel groups while keeping backplane power draw capped at 110 mA at 5 VDC. Internal firmware flash compatibility ensures synchronized CPU logic execution with real-time LED status reflection across active sinking load paths.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the backplane current draw for the IC694MDL741 when all 16 channels are active?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 110 mA from the internal 5 VDC backplane bus when all 16 output channels are in the ON state.\u003c\/p\u003e\n\u003cp\u003eQ: What are the current capacity limits per point and per common group on this module?\u003c\/p\u003e\n\u003cp\u003eA: Each individual channel supports up to 0.5 A output current, with a total maximum rating of 2.0 A per 8-channel common group.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation level exists between the two output channel groups?\u003c\/p\u003e\n\u003cp\u003eA: The module provides group-to-group optical isolation rated at 250 VAC continuous and 1500 VAC for 1 minute.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the PACSystem RX3i rack prior to inserting or removing the IC694MDL741 module to avoid damage to backplane connector pins.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the selected rack slot and press firmly until the top and bottom mounting latches snap into place on the baseplate.\u003c\/li\u003e\n\u003cli\u003eWire the field loads observing negative logic (sinking output) conventions, ensuring external 12\/24 VDC power connections do not exceed the +20% upper voltage boundary.\u003c\/li\u003e\n\u003cli\u003eSeparate DC signal wiring from high-voltage AC cables inside the panel ducting to minimize electromagnetic noise coupling onto field circuits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43724932415578,"sku":"IC694MDL741","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC694MDL741.png?v=1784881936","url":"https:\/\/www.spareoil.com\/products\/ic694mdl741-ge-fanuc-pacsystem-rx3i-discrete-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}