{"product_id":"ic695alg728-ge-fanuc-pacsystems-rx3i-analog-output-module","title":"IC695ALG728 GE Fanuc PACSystems RX3i Analog Output Module","description":"\u003cp\u003eConfigured for precision field signal control and instrument loop driving in PACSystems RX3i platforms, the \u003cstrong\u003eGE Fanuc IC695ALG728\u003c\/strong\u003e (\u003cstrong\u003eIC695ALG728\u003c\/strong\u003e Non-Isolated Analog Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG728\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ As specified on hardware label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e12.00 lbs (5.44 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard single RX3i I\/O slot footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e380 mA max @ 3.3 VDC backplane power (HART enabled); 315 mA @ 24 VDC (isolated); 7.25 W max dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8 non-isolated output channels (4 channels per HART modem)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Outputs\u003c\/td\u003e\n\u003ctd\u003e+\/-10 VDC, 0 to 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Outputs\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Resolution\u003c\/td\u003e\n\u003ctd\u003e+\/-10V: 15.9 bits; 0-10V: 14.9 bits; 0-20mA: 15.9 bits; 4-20mA: 15.6 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Update Rate\u003c\/td\u003e\n\u003ctd\u003e8 ms approximate (all 8 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e+19.2 VDC to +30 VDC (+24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e2550 VDC field-to-backplane for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eHighway Addressable Remote Transducer (HART) Protocol Version 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC695ALG728 integrates two onboard HART modems to support HART Protocol Version 5.0 pass-through, converting dynamic IEEE 32-bit floating point or 16-bit integer data structures across 8 output channels. Executing an analog update rate of 8 ms across all outputs, the module manages current and voltage signal transitions without impacting backplane bus communication velocity. Firmware flash compatibility ensures synchronized parameter execution during system boot sequences and loop configuration updates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power sources are required to run the IC695ALG728 analog output module?\u003c\/p\u003e\n\u003cp\u003eA: The module requires both backplane power (up to 380 mA at 3.3 VDC with HART enabled) and an external user power supply ranging from +19.2 to +30 VDC (+24 VDC nominal).\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum load impedance supported for current output loops on the IC695ALG728?\u003c\/p\u003e\n\u003cp\u003eA: The current output drivers support a maximum connected field load of 850 Ohms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect backplane power and external 24 VDC user supply lines before inserting or removing the module from the RX3i backplane rack.\u003c\/li\u003e\n\u003cli\u003eLand field output wiring on the designated terminal block assembly, maintaining channel polarity for 0-20 mA, 4-20 mA, and +\/-10 VDC field loops.\u003c\/li\u003e\n\u003cli\u003eGround all field cable shielding at the system grounding bar to maintain signal integrity and prevent high-frequency noise interference.\u003c\/li\u003e\n\u003cli\u003eEnsure external 24 VDC field power supply lines do not exceed the +19.2 VDC to +30 VDC operating window under full load conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43712725287002,"sku":"IC695ALG728","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC695ALG7281.png?v=1784777001","url":"https:\/\/www.spareoil.com\/products\/ic695alg728-ge-fanuc-pacsystems-rx3i-analog-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}