{"product_id":"ic695pbm300-ge-pacsystems-rx3i-profibus-master-module","title":"IC695PBM300 GE PACSystems RX3i PROFIBUS Master Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC695PBM300\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695PBM300\u003c\/strong\u003e PROFIBUS Master Module, operates as a dedicated hardware component for deterministic fieldbus communication execution within PACSystems RX3i PCI backplane architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695PBM300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg (0.31 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot PACSystems RX3i module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.45 W maximum (440 mA @ 3.3 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Interface\u003c\/td\u003e\n\u003ctd\u003eRX3i Universal Backplane (PCI connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003e1 PROFIBUS Master Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP, DP-V1 Read\/Write\/Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Slave Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 125 PROFIBUS DP slaves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Data Exchange Capacity\u003c\/td\u003e\n\u003ctd\u003e3584 Bytes maximum input data, 3584 Bytes maximum output data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePer-Slave Exchange Limit\u003c\/td\u003e\n\u003ctd\u003e244 Bytes input data, 244 Bytes output data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Baud Rates\u003c\/td\u003e\n\u003ctd\u003e9.6 kBit\/s, 19.2 kBit\/s, 93.75 kBit\/s, 187.5 kBit\/s, 500 kBit\/s, 1.5 MBit\/s, 3 MBit\/s, 6 MBit\/s, 12 MBit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Control Modes\u003c\/td\u003e\n\u003ctd\u003eSync mode, Freeze mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Firmware Requirements\u003c\/td\u003e\n\u003ctd\u003eRX3i Controller Firmware v2.90 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics \u0026amp; Status Data\u003c\/td\u003e\n\u003ctd\u003eSlave Status Bit Array Table, Network Diagnostic Counters, DP Master Diagnostic Counters, Slave Diagnostic Address\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS OK LED, Network LED, MOD Status LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Velocity \u0026amp; Deterministic Network Execution\u003c\/h3\u003e\n\u003cp\u003eThe module manages high-speed fieldbus data transfers over Profinet \/ EtherNet\/IP deterministic networks and PCI backplane bus interfaces. Operating across configurable baud rates up to 12 MBit\/s, the hardware maintains backplane bus communication velocity while maintaining firmware flash compatibility via indirect updates using the host controller and WinLoader utility.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane power supply requirements for the IC695PBM300?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 440 mA exclusively from the 3.3 VDC backplane power rail on the RX3i PCI universal backplane.\u003c\/p\u003e\n\u003cp\u003eQ: How is firmware updated on the IC695PBM300 module?\u003c\/p\u003e\n\u003cp\u003eA: Firmware flash upgrades are performed indirectly through the host RX3i controller utilizing the WinLoader software utility.\u003c\/p\u003e\n\u003cp\u003eQ: What system software and CPU firmware versions are required to run the IC695PBM300?\u003c\/p\u003e\n\u003cp\u003eA: The host RX3i controller must run firmware version 2.90 or higher to support communications with the module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Mount the IC695PBM300 into a designated universal backplane slot of the PACSystems RX3i rack, ensuring the rear PCI edge connector aligns correctly before locking top and bottom retention clips.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Termination:\u003c\/strong\u003e Connect standard RS-485 PROFIBUS cables using DB9 connectors. Ensure bus termination resistors are enabled on the physical end nodes of the segment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Secure cable shielding directly to the cable connector metal shell and grounded DIN-rail chassis to eliminate common-mode signal interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHost Synchronization:\u003c\/strong\u003e Configure the module within Proficy Machine Edition and verify communication status via the front panel OK, Network, and MOD LEDs after backplane power-up.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43683834232922,"sku":"IC695PBM300","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC695PBM300.png?v=1784599349","url":"https:\/\/www.spareoil.com\/products\/ic695pbm300-ge-pacsystems-rx3i-profibus-master-module","provider":"SpareOil Automation","version":"1.0","type":"link"}