{"product_id":"ic697alg440-ge-series-90-70-analog-input-expander-module","title":"IC697ALG440 GE Series 90-70 Analog Input Expander Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC697ALG440\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697ALG440\u003c\/strong\u003e Analog Input Expander Module, operates as a dedicated hardware component for 4 to 20 mA current loop processing and multiplexed expansion within Series 90-70 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697ALG440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg (1.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-Slot Series 90-70 Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.4 A (2 W) at +5 VDC (from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries 90-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e2.4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.07% of full scale, +\/- 0.1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Calibration\u003c\/td\u003e\n\u003ctd\u003eFactory set at 10 VDC +\/- 2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Features\u003c\/td\u003e\n\u003ctd\u003eExpander channel response detection, module health diagnostics, status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and System Integration\u003c\/h3\u003e\n\u003cp\u003eThe IC697ALG440 utilizes an integrated analog multiplexer to switch current inputs sequentially to an analog-to-digital converter managed by a paired base converter module. System expansion allows combinations of expander units linked to a base converter module to scale up to 120 input channels within a single analog subsystem. High-speed backplane bus communication velocity guarantees rapid data transfer of converted 2's complement 16-bit digital values to the CPU backplane.\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility across Series 90-70 host CPUs enables seamless detection of module health and channel response diagnostics. Differential communication signals interface between the base converter and expander units via dedicated serial bus terminals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the backplane power consumption for the IC697ALG440?\u003c\/p\u003e\n\u003cp\u003eA: The module requires 0.4 A (2 W) at +5 VDC directly from the backplane power bus.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum channel density supported when combining expander modules with a base converter?\u003c\/p\u003e\n\u003cp\u003eA: A single base converter module can interface with expander modules to support up to 120 total input channels.\u003c\/p\u003e\n\u003cp\u003eQ: How is physical placement restricted for expander modules in the rack?\u003c\/p\u003e\n\u003cp\u003eA: The IC697ALG440 must be located in the same backplane rack and adjacent to the base converter or interconnecting expander modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlways de-energize rack backplane power before inserting or removing the module from the chassis.\u003c\/li\u003e\n\u003cli\u003eMount the module directly adjacent to its associated base converter or preceding expander module within the same rack structure.\u003c\/li\u003e\n\u003cli\u003eWire 4 to 20 mA current loops maintaining correct polarity across differential serial bus connections.\u003c\/li\u003e\n\u003cli\u003eConnect signal cable shields to terminal 35 of the base converter module when using shielded cabling to prevent noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43698866847834,"sku":"IC697ALG440","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC697ALG440.png?v=1784690567","url":"https:\/\/www.spareoil.com\/products\/ic697alg440-ge-series-90-70-analog-input-expander-module","provider":"SpareOil Automation","version":"1.0","type":"link"}